Albumin Acts As a Lubricant on the Surface of Hydrogel and Silicone Hydrogel Contact Lenses

Overview
Publisher MDPI
Date 2021 Jul 2
PMID 34201543
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Feeling comfortable is the greatest concern for contact lens wearers, and it has been suggested that in vivo comfort could be corresponded to the in vitro friction coefficient of contact lenses. How tear albumin could affect the friction coefficient of silicone hydrogel and hydrogel contact lenses was analyzed by sliding a lens against a quartz glass in normal and extremely high concentration of albumin solution. Albumin deposition testing and surface roughness analysis were also conducted. The results showed that the friction coefficient of tested contact lenses did not correspond to both the albumin deposition amount and surface roughness, but we proposed a model of how albumin might act as a lubricant on the surface of some hydrogel and silicone hydrogel contact lenses. In conclusion, albumin provided lubrication for silicone hydrogel contact lenses regardless of albumin concentrations, while albumin only acted as a lubricant for hydrogel contact under normal concentration.

Citing Articles

Contact lens as an emerging platform for ophthalmic drug delivery: A systematic review.

Yang H, Zhao M, Xing D, Zhang J, Fang T, Zhang F Asian J Pharm Sci. 2023; 18(5):100847.

PMID: 37915758 PMC: 10616140. DOI: 10.1016/j.ajps.2023.100847.


Biomimetic-Engineered Silicone Hydrogel Contact Lens Materials.

Ishihara K, Shi X, Fukazawa K, Yamaoka T, Yao G, Wu J ACS Appl Bio Mater. 2023; 6(9):3600-3616.

PMID: 37616500 PMC: 10521029. DOI: 10.1021/acsabm.3c00296.

References
1.
Sterner O, Aeschlimann R, Zurcher S, Lorenz K, Kakkassery J, Spencer N . Friction Measurements on Contact Lenses in a Physiologically Relevant Environment: Effect of Testing Conditions on Friction. Invest Ophthalmol Vis Sci. 2016; 57(13):5383-5392. DOI: 10.1167/iovs.16-19713. View

2.
Tiffany J . Tears in health and disease. Eye (Lond). 2003; 17(8):923-6. DOI: 10.1038/sj.eye.6700566. View

3.
Garrett Q, Laycock B, Garrett R . Hydrogel lens monomer constituents modulate protein sorption. Invest Ophthalmol Vis Sci. 2000; 41(7):1687-95. View

4.
Ajayi B, Kio F, Otajevwo F . Adhesive capabilities of Staphylococcus aureus and Pseudomonas aeruginosa isolated from tears of HIV/AIDS patients to soft contact lenses. Glob J Health Sci. 2012; 4(1):140-8. PMC: 4777024. DOI: 10.5539/gjhs.v4n1p140. View

5.
Choy C, Cho P, Benzie I, Ng V . Effect of one overnight wear of orthokeratology lenses on tear composition. Optom Vis Sci. 2004; 81(6):414-20. DOI: 10.1097/01.opx.0000135094.15125.4c. View