Clinical Evaluation of the Torq Zero Delay Centrifuge System for Decentralized Blood Collection and Stabilization

Overview
Specialty Radiology
Date 2021 Jul 2
PMID 34199408
Authors
Affiliations
Soon will be listed here.
Abstract

Blood sample collection and rapid separation-critical preanalytical steps in clinical chemistry-can be challenging in decentralized collection settings. To address this gap, the Torq™ zero delay centrifuge system includes a lightweight, hand-portable centrifuge (ZDrive™) and a disc-shaped blood collection device (ZDisc™) enabling immediate sample centrifugation at the point of collection. Here, we report results from clinical validation studies comparing performance of the Torq System with a conventional plasma separation tube (PST). Blood specimens from 134 subjects were collected and processed across three independent sites to compare ZDisc and PST performance in the assessment of 14 analytes (K, Na, Cl, Ca, BUN, creatinine, AST, ALT, ALP, total bilirubin, albumin, total protein, cholesterol, and triglycerides). A 31-subject precision study was performed to evaluate reproducibility of plasma test results from ZDiscs, and plasma quality was assessed by measuring hemolysis and blood cells from 10 subject specimens. The ZDisc successfully collected and processed samples from 134 subjects. ZDisc results agreed with reference PSTs for all 14 analytes with mean % biases well below clinically significant levels. Results were reproducible across different operators and ZDisc production lots, and plasma blood cell counts and hemolysis levels fell well below clinical acceptance thresholds. ZDiscs produce plasma samples equivalent to reference PSTs. Results support the suitability of the Torq System for remotely collecting and processing blood samples in decentralized settings.

References
1.
Daves M, Trevisan D, Cemin R . Different collection tubes in cardiac biomarkers detection. J Clin Lab Anal. 2008; 22(6):391-4. PMC: 6648962. DOI: 10.1002/jcla.20277. View

2.
Malinauskas R . Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices. Artif Organs. 1998; 21(12):1255-67. DOI: 10.1111/j.1525-1594.1997.tb00486.x. View

3.
Faivre M, Abkarian M, Bickraj K, Stone H . Geometrical focusing of cells in a microfluidic device: an approach to separate blood plasma. Biorheology. 2006; 43(2):147-59. View

4.
Yang S, Undar A, Zahn J . A microfluidic device for continuous, real time blood plasma separation. Lab Chip. 2006; 6(7):871-80. DOI: 10.1039/b516401j. View

5.
Babic N, Zibrat S, Gordon I, Lee C, Yeo K . Effect of blood collection tubes on the incidence of artifactual hyperkalemia on patient samples from an outreach clinic. Clin Chim Acta. 2012; 413(19-20):1454-8. DOI: 10.1016/j.cca.2012.06.001. View