Highly Selective and Sensitive Sandwich Immunosensor Platform Modified with MUA-capped GNPs for Detection of Spike Receptor Binding Domain Protein: A Precious Marker of COVID 19 Infection

Overview
Date 2021 Jun 30
PMID 34188361
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

A label-free electrochemical biosensing system as a suitable analysis technique for COVID 19 specific spike receptor-binding domain protein (RBD) was developed with an aim to facilitate the diagnosis of coronavirus. A novel production procedure for the fabrication of gold nanoparticles (GNPs)-capped 11-mercaptoundecanoic acid (MUA) modified bioelectrode was presented and its application potential for RBD biosensing was examined. The bioelectrode fabrication protocol was based on covalent ester linking formation between hydroxylated ITO electrode and GNPs-capped MUA () with carboxyl ends. For this aim, spherical GNPs were prepared and characterized with scanning-transmission electron microscopy (S-TEM), UV-vis, and Raman spectroscopy. The synthesized GNPs were functionalized with MUA yielding Au-S bonds. Then, covalent immobilization of anti-RBD antibodies on the was performed with the help of carbodiimide coupling chemistry. The assembly processes of anti-RBD antibodies and RBD antigens were characterized electrochemical, chemical and morphological techniques. was used as immobilization environment and provided the most effective surface design for target immunosensor. The resulting immunosensor is further applied to the impedimetric detection of RBD and it displayed a linear response to RBD antigen in the linear range of 0.002-100 pg mL with a limit of detection of 0.577 fg mL and sensitivity of 0.238 kohmpgmL cm. The fabricated immunosensor had a good repeatability, long storage, stability and a reusable property after simple regeneration process. Furthermore, it was successfully employed for selective determination of RBD in artificial nasal secretion samples.

Citing Articles

Coronavirus Anatomy and Its Analytical Approaches for Targeting COVID-19.

Ramanathan S, Malarvili M, Gopinath S, Nindhia T Adv Exp Med Biol. 2024; 1457:33-44.

PMID: 39283419 DOI: 10.1007/978-3-031-61939-7_2.


Chitosan-enhanced sensitivity of mercaptoundecanoic acid (MUA)- capped gold nanorod based localized surface plasmon resonance (LSPR) biosensor for detection of alpha-synuclein oligomer biomarker in parkinson's disease.

Apaydin B, Camoglu T, Canbek Ozdil Z, Gezen-Ak D, Ege D, Gulsoy M Biotechnol Appl Biochem. 2024; 72(1):150-163.

PMID: 39228174 PMC: 11798540. DOI: 10.1002/bab.2653.


Hierarchical Nanobiosensors at the End of the SARS-CoV-2 Pandemic.

Medrano-Lopez J, Villalpando I, Salazar M, Torres-Torres C Biosensors (Basel). 2024; 14(2).

PMID: 38392027 PMC: 10887370. DOI: 10.3390/bios14020108.


COVID-19 impedimetric biosensor based on polypyrrole nanotubes, nickel hydroxide and VHH antibody fragment: specific, sensitive, and rapid viral detection in saliva samples.

Santos A, Macedo de Souza Brandao A, Hryniewicz B, Abreu H, Bach-Toledo L, Schuster da Silva S Mater Today Chem. 2023; 30:101597.

PMID: 37284350 PMC: 10236006. DOI: 10.1016/j.mtchem.2023.101597.


Using Nanomaterials for SARS-CoV-2 Sensing via Electrochemical Techniques.

Tieu M, Le H, Cho S Micromachines (Basel). 2023; 14(5).

PMID: 37241556 PMC: 10221901. DOI: 10.3390/mi14050933.


References
1.
Kaushik A, Dhau J, Gohel H, Mishra Y, Kateb B, Kim N . Electrochemical SARS-CoV-2 Sensing at Point-of-Care and Artificial Intelligence for Intelligent COVID-19 Management. ACS Appl Bio Mater. 2022; 3(11):7306-7325. DOI: 10.1021/acsabm.0c01004. View

2.
Tripathy S, Yu Y . Spectroscopic investigation of S-Ag interaction in omega-mercaptoundecanoic acid capped silver nanoparticles. Spectrochim Acta A Mol Biomol Spectrosc. 2009; 72(4):841-4. DOI: 10.1016/j.saa.2008.12.004. View

3.
Pashai E, Najafpour Darzi G, Jahanshahi M, Yazdian F, Rahimnejad M . An electrochemical nitric oxide biosensor based on immobilized cytochrome c on a chitosan-gold nanocomposite modified gold electrode. Int J Biol Macromol. 2017; 108:250-258. DOI: 10.1016/j.ijbiomac.2017.11.157. View

4.
Vadlamani B, Uppal T, Verma S, Misra M . Functionalized TiO Nanotube-Based Electrochemical Biosensor for Rapid Detection of SARS-CoV-2. Sensors (Basel). 2020; 20(20). PMC: 7589637. DOI: 10.3390/s20205871. View

5.
Rodriguez-Moncayo R, Cedillo-Alcantar D, Guevara-Pantoja P, Chavez-Pineda O, Hernandez-Ortiz J, Amador-Hernandez J . A high-throughput multiplexed microfluidic device for COVID-19 serology assays. Lab Chip. 2020; 21(1):93-104. DOI: 10.1039/d0lc01068e. View