» Articles » PMID: 34173078

Micro-CT Evaluation of Rotary and Reciprocating Glide Path and Shaping Systems Outcomes in Maxillary Molar Curved Canals

Overview
Journal Odontology
Specialty Dentistry
Date 2021 Jun 26
PMID 34173078
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The shaping outcomes after instrumentation with rotary and reciprocating glide path and shaping systems were evaluated through micro-computed tomography (Micro-CT). Thirty extracted maxillary first molars were selected. Mesio-buccal canals were randomized into two groups (n = 15): rotary system ProGlider and ProTaper Next X1, X2 (PG-PTN) and reciprocating system WaveOne Gold Glider and WaveOne Gold Primary (WOGG-WOG). Specimens were micro-CT scanned before, after glide path and after shaping. Increase in canal volume and surface area, percentage of removed dentin from the inner curvature, centroid shift and canal geometry variation through ratio of diameter ratios (RDR) and ratio of cross-sectional areas (RA) were measured in the apical and coronal levels and at the point of maximum curvature. The number of pecking motions needed to reach the working length (WL) was recorded. One-way ANOVA and post hoc Turkey-Kramer tests were used (p < 0.05). Post-glide path analysis revealed that in the coronal third, RDR was more favorable to PG and centroid shift was lower for WOGG in the apical third. Post-shaping analysis showed a reduced removal of dentin and a more favorable RA for PTN at point of maximum curvature. The number of pecking motions up to WL resulted in different between groups both for glide path and shaping phases. Despite a higher dentin removal for reciprocating instruments at the point of maximum curvature, both systems seemed to produce well-centered glide path and shaping outcomes. Rotary and reciprocating systems seemed able to respect the original canal anatomy.

Citing Articles

Brushing motion caused no microcracks: a micro-computed tomography study.

Yanik D, Ozel S, Dagli Tasman Comert F Clin Oral Investig. 2025; 29(3):173.

PMID: 40063146 PMC: 11893623. DOI: 10.1007/s00784-025-06253-0.


Comparison of mechanical properties and shaping performance of ProGlider and ProTaper ultimate slider.

Song J, Jang J, Chang S, Chung S, Oh S BMC Oral Health. 2025; 25(1):59.

PMID: 39799311 PMC: 11725211. DOI: 10.1186/s12903-025-05422-7.


Exploring the Impact of Access Cavity Designs on Canal Orifice Localization and Debris Presence: A Scoping Review.

Dioguardi M, La Notte D, Sovereto D, Quarta C, Ballini A, Crincoli V Clin Exp Dent Res. 2024; 10(6):e70013.

PMID: 39578410 PMC: 11584341. DOI: 10.1002/cre2.70013.


Glide Path in Endodontics: A Literature Review of Current Knowledge.

Lup V, Malvicini G, Gaeta C, Grandini S, Ciavoi G Dent J (Basel). 2024; 12(8).

PMID: 39195101 PMC: 11352993. DOI: 10.3390/dj12080257.


Influence of Cavity Designs on Fracture Resistance: Analysis of the Role of Different Access Techniques to the Endodontic Cavity in the Onset of Fractures: Narrative Review.

Dioguardi M, La Notte D, Sovereto D, Quarta C, Martella A, Ballini A ScientificWorldJournal. 2024; 2024:1648011.

PMID: 39109329 PMC: 11303043. DOI: 10.1155/2024/1648011.


References
1.
Schilder H . Cleaning and shaping the root canal. Dent Clin North Am. 1974; 18(2):269-96. View

2.
Peters O . Current challenges and concepts in the preparation of root canal systems: a review. J Endod. 2004; 30(8):559-67. DOI: 10.1097/01.don.0000129039.59003.9d. View

3.
Berutti E, Negro A, Lendini M, Pasqualini D . Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments. J Endod. 2004; 30(4):228-30. DOI: 10.1097/00004770-200404000-00011. View

4.
Varela Patino P, Biedma B, Liebana C, Cantatore G, Bahillo J . The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod. 2005; 31(2):114-6. DOI: 10.1097/01.don.0000136209.28647.13. View

5.
Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G . Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals. J Endod. 2009; 35(3):408-12. DOI: 10.1016/j.joen.2008.11.021. View