» Articles » PMID: 34172772

Simultaneous Multi-nuclide Imaging Via Double-photon Coincidence Method with Parallel Hole Collimators

Overview
Journal Sci Rep
Specialty Science
Date 2021 Jun 26
PMID 34172772
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Multi-tracer imaging can provide useful information in the definitive diagnosis and research of medical, biological, and pharmaceutical sciences. Single-photon emission computed tomography (SPECT) is one of the nuclear medicine imaging modalities widely used for diagnosis or medical research and has a multi-tracer imaging capability. One of the drawbacks of multi-tracer imaging is crosstalk from other gamma rays, which affects the reconstructed image. Scattering correction methods, such as the dual- and triple-energy window methods, are used for conventional SPECT imaging to reduce the background caused by the crosstalk. This study proposes another crosstalk reduction method. Some nuclides emit two or more gamma rays through intermediate levels. Thus, detecting these gamma rays with the coincidence method allows us to distinguish a true gamma ray signal and a background signal. The nuclide position can be estimated at the intersection of two gamma rays using collimators. We demonstrate herein simultaneous In and Lu imaging via the double-photon coincidence method using GAGG detectors and parallel hole collimators. The double-photon coincidence method greatly reduces the background caused by other gamma rays and offers higher-quality images than does conventional imaging.

Citing Articles

Current and potential roles of immuno-PET/-SPECT in CAR T-cell therapy.

Mulgaonkar A, Udayakumar D, Yang Y, Harris S, Oz O, Ramakrishnan Geethakumari P Front Med (Lausanne). 2023; 10:1199146.

PMID: 37441689 PMC: 10333708. DOI: 10.3389/fmed.2023.1199146.


Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera.

Uenomachi M, Takahashi M, Shimazoe K, Takahashi H, Kamada K, Orita T Sci Rep. 2021; 11(1):17933.

PMID: 34504184 PMC: 8429650. DOI: 10.1038/s41598-021-97302-7.

References
1.
Tsuji A, Kojima A, Matsumoto M, Oyama Y, Tomiguchi S, Kira T . A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123. Ann Nucl Med. 1999; 13(5):317-23. DOI: 10.1007/BF03164870. View

2.
Linden O, Hindorf C, Cavallin-Stahl E, Wegener W, Goldenberg D, Horne H . Dose-fractionated radioimmunotherapy in non-Hodgkin's lymphoma using DOTA-conjugated, 90Y-radiolabeled, humanized anti-CD22 monoclonal antibody, epratuzumab. Clin Cancer Res. 2005; 11(14):5215-22. DOI: 10.1158/1078-0432.CCR-05-0172. View

3.
Mouden M, Timmer J, Ottervanger J, Reiffers S, Oostdijk A, Knollema S . Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: fewer equivocal results and lower radiation dose. Eur J Nucl Med Mol Imaging. 2012; 39(6):1048-55. DOI: 10.1007/s00259-012-2086-z. View

4.
Buck A, Nekolla S, Ziegler S, Beer A, Krause B, Herrmann K . SPECT/CT. J Nucl Med. 2008; 49(8):1305-19. DOI: 10.2967/jnumed.107.050195. View

5.
Ichihara T, Ogawa K, Motomura N, Kubo A, Hashimoto S . Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT. J Nucl Med. 1993; 34(12):2216-21. View