European Guideline on Indications, Performance and Clinical Impact of C-breath Tests in Adult and Pediatric Patients: An EAGEN, ESNM, and ESPGHAN Consensus, Supported by EPC

Abstract

Introduction: C-breath tests are valuable, noninvasive diagnostic tests that can be widely applied for the assessment of gastroenterological symptoms and diseases. Currently, the potential of these tests is compromised by a lack of standardization regarding performance and interpretation among expert centers.

Methods: This consensus-based clinical practice guideline defines the clinical indications, performance, and interpretation of C-breath tests in adult and pediatric patients. A balance between scientific evidence and clinical experience was achieved by a Delphi consensus that involved 43 experts from 18 European countries. Consensus on individual statements and recommendations was established if ≥ 80% of reviewers agreed and <10% disagreed.

Results: The guideline gives an overview over general methodology of C-breath testing and provides recommendations for the use of C-breath tests to diagnose Helicobacter pylori infection, measure gastric emptying time, and monitor pancreatic exocrine and liver function in adult and pediatric patients. Other potential applications of C-breath testing are summarized briefly. The recommendations specifically detail when and how individual C-breath tests should be performed including examples for well-established test protocols, patient preparation, and reporting of test results.

Conclusion: This clinical practice guideline should improve pan-European harmonization of diagnostic approaches to symptoms and disorders, which are very common in specialist and primary care gastroenterology practice, both in adult and pediatric patients. In addition, this guideline identifies areas of future clinical research involving the use of C-breath tests.

Citing Articles

Diabetic gastroenteropathy: a pan-alimentary complication.

Kornum D, Krogh K, Keller J, Malagelada C, Drewes A, Brock C Diabetologia. 2025; .

PMID: 39934370 DOI: 10.1007/s00125-025-06365-y.


Breath Test via Mid-Infrared Sensor Technology.

Flores Rangel G, Diaz de Leon Martinez L, Mizaikoff B ACS Sens. 2025; 10(2):1005-1010.

PMID: 39921651 PMC: 11877511. DOI: 10.1021/acssensors.4c02785.


European guidelines for the diagnosis and treatment of pancreatic exocrine insufficiency: UEG, EPC, EDS, ESPEN, ESPGHAN, ESDO, and ESPCG evidence-based recommendations.

Dominguez-Munoz J, Vujasinovic M, de la Iglesia D, Cahen D, Capurso G, Gubergrits N United European Gastroenterol J. 2024; 13(1):125-172.

PMID: 39639485 PMC: 11866322. DOI: 10.1002/ueg2.12674.


Feeding Intolerance-A Key Factor in the Management of Acute Pancreatitis: A Review.

Gorski P, Swidnicka-Siergiejko A J Clin Med. 2024; 13(21).

PMID: 39518500 PMC: 11546861. DOI: 10.3390/jcm13216361.


AGA-PancreasFest Joint Symposium on Exocrine Pancreatic Insufficiency.

Whitcomb D, Duggan S, Martindale R, Lowe M, Stallings V, Conwell D Gastro Hep Adv. 2024; 2(3):395-411.

PMID: 39132652 PMC: 11307793. DOI: 10.1016/j.gastha.2022.11.008.


References
1.
. American Gastroenterological Association medical position statement: guidelines for the evaluation and management of chronic diarrhea. Gastroenterology. 1999; 116(6):1461-3. DOI: 10.1016/s0016-5085(99)70512-3. View

2.
Ling S, Amarri S, Slater C, Hollman A, Preston T, Weaver L . Liver disease does not affect lipolysis as measured with the 13C-mixed triacylglycerol breath test in children with cystic fibrosis. J Pediatr Gastroenterol Nutr. 2000; 30(4):368-72. DOI: 10.1097/00005176-200004000-00004. View

3.
Maes B, Ghoos Y, Geypens B, Hiele M, Rutgeerts P . Relation between gastric emptying rate and energy intake in children compared with adults. Gut. 1995; 36(2):183-8. PMC: 1382401. DOI: 10.1136/gut.36.2.183. View

4.
Camilleri M, Parkman H, Shafi M, Abell T, Gerson L . Clinical guideline: management of gastroparesis. Am J Gastroenterol. 2012; 108(1):18-37. PMC: 3722580. DOI: 10.1038/ajg.2012.373. View

5.
Eaton S, Pacilli M, Wood J, McHoney M, Corizia L, Kingsley C . Factors affecting 13C-natural abundance measurement of breath carbon dioxide during surgery: absorption of carbon dioxide during endoscopic procedures. Rapid Commun Mass Spectrom. 2008; 22(11):1759-62. DOI: 10.1002/rcm.3572. View