» Articles » PMID: 34127727

Changes in the Geometry of Modern Daily Disposable Soft Contact Lenses During Wear

Overview
Journal Sci Rep
Specialty Science
Date 2021 Jun 15
PMID 34127727
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The geometry of contact lenses can be altered by wear but determining the changes that occur in soft contact lenses (SCLs) is challenging. This study aimed to investigate the shape alterations of daily disposable SCLs after wear using swept-source optical coherence tomography (SS-OCT). Forty-five eyes with myopia of - 3.00 diopters (D) were enrolled. The participants wore three types of SCLs: hydrogel lens (nesofilcon A) and silicone hydrogel lenses (delefilcon A and stenfilcon A). The SCLs were scanned 3-6 min after lens removal. We found a significant decrease in the SCL anterior curvature: 0.24 ± 0.17 mm for nesofilcon A, 0.44 ± 0.21 mm for delefilcon A, and 0.53 ± 0.29 mm for stenfilcon A. The changes in the anterior curvature of SCLs correlated moderately with the mean corneal keratometry; Pearson's correlation coefficients for nesofilcon A and delefilcon A were 0.57 and 0.52, respectively (P < 0.001). A statistically significant change in the total diameter was observed in SCL made of stenfilcon A (0.39 mm, P < 0.001). To conclude, the central radii of curvature decreased after a wearing period for all three types of daily disposable SCLs to imitate the anterior corneal surface, however, the changes in other geometrical parameters measured with SS-OCT were lens-specific.

Citing Articles

Application of Silicone in Ophthalmology: A Review.

Mladenovic T, Zivic F, Petrovic N, Njezic S, Pavic J, Kotorcevic N Materials (Basel). 2024; 17(14).

PMID: 39063747 PMC: 11278226. DOI: 10.3390/ma17143454.


Evaluation of Celligent Biomimetic Water Gradient Contact Lens Effects on Ocular Surface and Subjective Symptoms.

Capote-Puente R, Sanchez-Gonzalez J, Sanchez-Gonzalez M, Bautista-Llamas M Diagnostics (Basel). 2023; 13(7).

PMID: 37046476 PMC: 10093668. DOI: 10.3390/diagnostics13071258.


Swept-source OCT for corneal graft quantitative evaluation in the eye bank and the correlation of the measurements to pre-excision values.

Kaluzny B, Mlyniuk P, Liberski S, Jimenez-Villar A, Machalinska A, Grulkowski I Sci Rep. 2022; 12(1):14834.

PMID: 36050445 PMC: 9437096. DOI: 10.1038/s41598-022-19225-1.

References
1.
Chalmers R . Overview of factors that affect comfort with modern soft contact lenses. Cont Lens Anterior Eye. 2013; 37(2):65-76. DOI: 10.1016/j.clae.2013.08.154. View

2.
Morgan P, Efron N . In vivo dehydration of silicone hydrogel contact lenses. Eye Contact Lens. 2003; 29(3):173-6. DOI: 10.1097/01.ICL.0000072825.23491.59. View

3.
Karnowski K, Grulkowski I, Mohan N, Cox I, Wojtkowski M . Quantitative optical inspection of contact lenses immersed in wet cell using swept source OCT. Opt Lett. 2014; 39(16):4727-30. DOI: 10.1364/OL.39.004727. View

4.
Kim E, Saha M, Ehrmann K . Mechanical Properties of Contact Lens Materials. Eye Contact Lens. 2017; 44 Suppl 2:S148-S156. DOI: 10.1097/ICL.0000000000000442. View

5.
Fujimoto J, Swanson E . The Development, Commercialization, and Impact of Optical Coherence Tomography. Invest Ophthalmol Vis Sci. 2016; 57(9):OCT1-OCT13. PMC: 4968928. DOI: 10.1167/iovs.16-19963. View