Abstract

A crystalline-fiber-based Mirau-type full-field optical coherence tomography (FF-OCT) system utilizing two partially coherent illumination modes is presented. Using a diode-pumped Ti:sapphire crystalline fiber with a high numerical aperture, spatially-incoherent broadband emission can be generated with high radiance. With two modes of different spatial coherence settings, either deeper penetration depth or higher B-scan rate can be achieved. In a wide-field illumination mode, the system functions like FF-OCT with partially coherent illumination to improve the penetration depth. In a strip-field illumination mode, a compressed field is generated on the sample, and a low-speckle B-scan can be acquired by compounding pixel lines within.

Citing Articles

Integration of cellular-resolution optical coherence tomography and Raman spectroscopy for discrimination of skin cancer cells with machine learning.

You C, Yi J, Hsu T, Huang S J Biomed Opt. 2023; 28(9):096005.

PMID: 37720189 PMC: 10500347. DOI: 10.1117/1.JBO.28.9.096005.


High-resolution full-field optical coherence tomography microscope for the evaluation of freshly excised skin specimens during Mohs surgery: A feasibility study.

Jain M, Chang S, Singh K, Kurtansky N, Huang S, Chen H J Biophotonics. 2023; 17(1):e202300275.

PMID: 37703431 PMC: 10841241. DOI: 10.1002/jbio.202300275.


Methods and applications of full-field optical coherence tomography: a review.

Wang L, Fu R, Xu C, Xu M J Biomed Opt. 2022; 27(5).

PMID: 35596250 PMC: 9122094. DOI: 10.1117/1.JBO.27.5.050901.

References
1.
Sacchet D, Brzezinski M, Moreau J, Georges P, Dubois A . Motion artifact suppression in full-field optical coherence tomography. Appl Opt. 2010; 49(9):1480-8. DOI: 10.1364/AO.49.001480. View

2.
Bonin T, Franke G, Hagen-Eggert M, Koch P, Huttmann G . In vivo Fourier-domain full-field OCT of the human retina with 1.5 million A-lines/s. Opt Lett. 2010; 35(20):3432-4. DOI: 10.1364/OL.35.003432. View

3.
Davis A, Levecq O, Azimani H, Siret D, Dubois A . Simultaneous dual-band line-field confocal optical coherence tomography: application to skin imaging. Biomed Opt Express. 2019; 10(2):694-706. PMC: 6377879. DOI: 10.1364/BOE.10.000694. View

4.
Karamata B, Lambelet P, Laubscher M, Salathe R, Lasser T . Spatially incoherent illumination as a mechanism for cross-talk suppression in wide-field optical coherence tomography. Opt Lett. 2004; 29(7):736-8. DOI: 10.1364/ol.29.000736. View

5.
Beaurepaire E, Boccara A, Lebec M, Blanchot L, Saint-Jalmes H . Full-field optical coherence microscopy. Opt Lett. 2007; 23(4):244-6. DOI: 10.1364/ol.23.000244. View