» Articles » PMID: 34110451

Posterior Capsular Opacification Evaluation Through Contrast Sensitivity Defocus Curves with Two Multifocal Intraocular Lenses of Similar Material

Overview
Specialty Ophthalmology
Date 2021 Jun 10
PMID 34110451
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To assess the degree of posterior capsular opacification (PCO) and its influence on contrast sensitivity defocus curve (CSDC) after implantation of two trifocal intraocular lenses (IOLs), Alsafit (AT) and Liberty (L), during a 12-month follow-up. A secondary aim was to evaluate the Nd:YAG capsulotomy rate in a long time.

Methods: Data from 63 subjects, 34 implanted with AT and 29 with L, were retrospectively analyzed for this pilot study. In those eyes without capsulotomy during the first year (n = 58), CSDC at 3 and 12 months after surgery and PCO grading were measured, with additional answering of a visual function questionnaire (VF-14) and a question of general satisfaction. The period after surgery up to capsulotomy or last on-demand visit without Nd:YAG was recorded for survival analysis beyond the 12-month follow-up.

Results: Total area under CSDC (TAUC) between 3 and 12 months decreased from 2.96 to 1.71 for AT (p < 0.05) and from 2.73 to 2.21 (p > 0.05) for L. Of eyes, 51.6, 19.3, and 29% with AT were graded as level 0, 1, and 2 of PCO, while 85.1, 11.1, and 3.7% of eyes with L were graded as level 0, 1, and 2 (p < 0.05). PCO grading was correlated with a decrease of TAUC (ρ =  - 0.27, p = 0.04). Median time to require capsulotomy was 22 months with AT and 30 months with L (p < 0.05).

Conclusions: PCO decreases CSDC in patients with trifocal lenses. Despite using the same hydrophilic material, PCO grading and Nd:YAG capsulotomy rate was higher for AT than for L.

Citing Articles

Innovative Polymeric Biomaterials for Intraocular Lenses in Cataract Surgery.

Wu K, Khammar R, Sheikh H, Marchand M J Funct Biomater. 2024; 15(12).

PMID: 39728191 PMC: 11678174. DOI: 10.3390/jfb15120391.


Approach to the design of different types of intraocular lenses based on an improved sinusoidal profile.

Xing Y, Liu Y, Li K, Li X, Liu D, Wang Y Biomed Opt Express. 2023; 14(6):2821-2838.

PMID: 37342725 PMC: 10278606. DOI: 10.1364/BOE.491762.


Geometric-phase intraocular lenses with multifocality.

Lee S, Park G, Kim S, Ryu Y, Yoon J, Hwang H Light Sci Appl. 2022; 11(1):320.

PMID: 36323667 PMC: 9630405. DOI: 10.1038/s41377-022-01016-y.


The Influence of Angle Alpha, Angle Kappa, and Optical Aberrations on Visual Outcomes after the Implantation of a High-Addition Trifocal IOL.

Cervantes-Coste G, Tapia A, Corredor-Ortega C, Osorio M, Valdez R, Massaro M J Clin Med. 2022; 11(3).

PMID: 35160346 PMC: 8836565. DOI: 10.3390/jcm11030896.

References
1.
Raulinajtys-Grzybek M, Grabska-Liberek I, Opala A, Slomka M, Chrobot M . Budget impact analysis of lens material on the posterior capsule opacification (PCO) as a complication after the cataract surgery. Cost Eff Resour Alloc. 2020; 18:19. PMC: 7296914. DOI: 10.1186/s12962-020-00214-y. View

2.
Elgohary M, Dowler J . Incidence and risk factors of Nd:YAG capsulotomy after phacoemulsification in non-diabetic and diabetic patients. Clin Exp Ophthalmol. 2006; 34(6):526-34. DOI: 10.1111/j.1442-9071.2006.01263.x. View

3.
Shah V, Russo C, Cannon R, Davidson R, Taravella M . Incidence of Nd:YAG capsulotomy after implantation of AcrySof multifocal and monofocal intraocular lenses: a case controlled study. J Refract Surg. 2010; 26(8):565-8. DOI: 10.3928/1081597X-20100303-01. View

4.
Parajuli A, Joshi P, Subedi P, Pradhan C . Effect of Nd:YAG laser posterior capsulotomy on intraocular pressure, refraction, anterior chamber depth, and macular thickness. Clin Ophthalmol. 2019; 13:945-952. PMC: 6559220. DOI: 10.2147/OPTH.S203677. View

5.
Cinar E, Yuce B, Aslan F, Erbakan G . Comparison of wavefront aberrations in eyes with multifocal and monofocal iols before and after Nd:YAG laser capsulotomy for posterior capsule opacification. Int Ophthalmol. 2020; 40(9):2169-2178. DOI: 10.1007/s10792-020-01397-2. View