Abstract

Background: Liver biopsy is a widely used, safe diagnostic tool utilised by clinicians for the histopathological assessment of the liver. Our study aims to report our experience in patients who underwent ultrasound-guided plugged percutaneous liver biopsy in a tertiary care hospital in India.

Material And Methods: The Institutional Ethical Review Board approved this retrospective study, and informed consent was obtained from all the patients. A total of 830 liver biopsies were performed between January 2014 and December 2018, of which 782 were plugged percutaneous liver biopsies. The tract was plugged using Gelfoam slurry. Various observations related to the procedures were recorded.

Results: Seven hundred and eighty-two were plugged percutaneous liver biopsies, which were performed during the study period. Of the 782 patients, 163 were male, and 619 were female (20.8 % and 79.2 %, respectively), with a mean age of 49.6 ± 2 years (1 month to 86 years). A 100% technical success rate was seen. No immediate major complications were documented in any of the patients who underwent plugged biopsies. No significant complications were seen in any patient.

Conclusions: Percutaneous liver biopsy is an extensively performed diagnostic tool. We found that ultrasound-guided percutaneous plugged liver biopsy is an easy to perform procedure, which is associated with a lower risk of a bleeding complications.

Citing Articles

Image-Guided Liver Biopsy: Perspectives from Interventional Radiology.

Ma J, Yu Q, Van Ha T Semin Intervent Radiol. 2024; 41(5):500-506.

PMID: 39664226 PMC: 11631366. DOI: 10.1055/s-0044-1792174.


Ultrasound-Guided Percutaneous Biopsy With Needle Track Plugging in Patients With Focal Liver Lesions on an Outpatient Basis: A Randomized Controlled Trial.

Yoon J, Lee C, Yoon H, Choi H, Kim S Korean J Radiol. 2024; 25(10):902-912.

PMID: 39344547 PMC: 11444846. DOI: 10.3348/kjr.2024.0536.


What is the Safe Observation Period for Image-Guided Percutaneous Liver Biopsies?.

Sehgal K, Taylor F, Van Wees M, Li K, De Boo D, Slater L Cardiovasc Intervent Radiol. 2024; 47(10):1327-1334.

PMID: 39078495 DOI: 10.1007/s00270-024-03800-2.


Ultrasound-guided percutaneous liver biopsy: A review of what operators need to know.

Alturkistani H, Alsergani A, Alzeer M, Alturkistani A, Zaini R, Bauones S Medicine (Baltimore). 2024; 103(30):e38673.

PMID: 39058859 PMC: 11272270. DOI: 10.1097/MD.0000000000038673.


Endoscopic Ultrasound-guided Liver Biopsy: Missing the Limitations in the Hype.

Choudhary N, Dhampalwar S, Sud S, Sharma Z, Sahu B, Saraf N J Clin Exp Hepatol. 2023; 14(1):101273.

PMID: 38076374 PMC: 10709297. DOI: 10.1016/j.jceh.2023.08.009.

References
1.
Atar E, Ben Ari Z, Bachar G, Amlinski Y, Neyman C, Knizhnik M . A comparison of transjugular and plugged-percutaneous liver biopsy in patients with contraindications to ordinary percutaneous liver biopsy and an "in-house" protocol for selecting the procedure of choice. Cardiovasc Intervent Radiol. 2009; 33(3):560-4. DOI: 10.1007/s00270-009-9743-z. View

2.
Chuah S . Liver biopsy--past, present and future. Singapore Med J. 1996; 37(1):86-90. View

3.
Kamphuisen P, Wiersma T, Mulder C, de Vries R . Plugged-percutaneous liver biopsy in patients with impaired coagulation and ascites. Pathophysiol Haemost Thromb. 2003; 32(4):190-3. DOI: 10.1159/000070426. View

4.
Ha T . Liver biopsy in liver transplant recipients. Semin Intervent Radiol. 2011; 21(4):271-4. PMC: 3036238. DOI: 10.1055/s-2004-861561. View

5.
Albeniz Arbizu E, Lopez San Roman A, Garcia Gonzalez M, Foruny Olcina J, Garcia-Hoz Rosales F, Marugan R . Fibrin-glue sealed liver biopsy in patients with a liver transplantation or in liver transplantation waiting list: preliminary results. Transplant Proc. 2003; 35(5):1911-2. DOI: 10.1016/s0041-1345(03)00588-8. View