» Articles » PMID: 34073353

Highly Sensitive and Selective Fluorescence "Turn-On" Detection of Pb (II) Based on FeO@Au-FITC Nanocomposite

Overview
Journal Molecules
Publisher MDPI
Specialty Biology
Date 2021 Jun 2
PMID 34073353
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

New nanocomposites, FeO@Au-FITC, were prepared and explored to develop a fluorescent detection of Pb. The FeO@AuNPs-FITC nanocomposites could be etched by Pb in the presence of NaSO, leading to fluorescence recovery of FITC quenched by FeO@Au nanocomposites. With the increase of Pb concentration, the fluorescence recovery of FeO@AuNPs-FITC increased gradually. Under optimized conditions, a detection limit of 5.2 nmol/L of Pb with a linear range of 0.02-2.0 µmol/L were obtained. The assay demonstrated negligible response to common metal ions. Recoveries of 98.2-106.4% were obtained when this fluorescent method was applied in detecting Pb spiked in a lake-water sample. The above results demonstrated the high potential of ion-induced nanomaterial etching in developing robust fluorescent assays.

Citing Articles

Facile synthesis of magnetic intelligent sensors for the pH-sensitive controlled capture of Cr(vi).

Hu P, Lu H, He Q, Ren F, Wu J, Jiang W RSC Adv. 2024; 14(27):19174-19184.

PMID: 38882477 PMC: 11177580. DOI: 10.1039/d4ra02695k.


Electrochemical sensors modified with iron oxide nanoparticles/nanocomposites for voltammetric detection of Pb (II) in water: A review.

Jjagwe J, Olupot P, Kulabako R, Carrara S Heliyon. 2024; 10(8):e29743.

PMID: 38665564 PMC: 11044046. DOI: 10.1016/j.heliyon.2024.e29743.


Photoluminescence Sensing of Soluble Lead in Children's Crayons Using Perovskite Nanocrystal In Situ Growth on an Aluminum Hydroxide Layer.

Zhang C, Wang S, Jin J, Luo H, Wang Y, Chen X Biosensors (Basel). 2023; 13(2).

PMID: 36831979 PMC: 9954079. DOI: 10.3390/bios13020213.


Highly sensitive and selective colorimetric detection of Pb(ii) ions using seed extract capped gold nanoparticles.

Huynh B, Doan V, Nguyen V, Nguyen A, Le V RSC Adv. 2022; 12(42):27116-27124.

PMID: 36276021 PMC: 9501858. DOI: 10.1039/d2ra04981c.


Lead Assays with Smartphone Detection Using a Monolithic Rod with 4-(2-Pyridylazo) Resorcinol.

Issarangkura Na Ayutthaya P, Yeerum C, Kesonkan K, Kiwfo K, Grudpan K, Teshima N Molecules. 2021; 26(18).

PMID: 34577191 PMC: 8466971. DOI: 10.3390/molecules26185720.

References
1.
Shi X, Gu W, Zhang C, Zhao L, Peng W, Xian Y . A label-free colorimetric sensor for Pb2+ detection based on the acceleration of gold leaching by graphene oxide. Dalton Trans. 2015; 44(10):4623-9. DOI: 10.1039/c4dt03883e. View

2.
Qi Z, Cheng Y, Xu Z, Chen M . Recent Advances in Porphyrin-Based Materials for Metal Ions Detection. Int J Mol Sci. 2020; 21(16). PMC: 7461582. DOI: 10.3390/ijms21165839. View

3.
Singh H, Bamrah A, Bhardwaj S, Deep A, Khatri M, Kim K . Nanomaterial-based fluorescent sensors for the detection of lead ions. J Hazard Mater. 2020; 407:124379. DOI: 10.1016/j.jhazmat.2020.124379. View

4.
Shu T, Su L, Wang J, Li C, Zhang X . Chemical etching of bovine serum albumin-protected Au25 nanoclusters for label-free and separation-free detection of cysteamine. Biosens Bioelectron. 2014; 66:155-61. DOI: 10.1016/j.bios.2014.10.073. View

5.
Liu W, Hou S, Yan J, Zhang H, Ji Y, Wu X . Quantification of proteins using enhanced etching of Ag coated Au nanorods by the Cu(2+)/bicinchoninic acid pair with improved sensitivity. Nanoscale. 2015; 8(2):780-4. DOI: 10.1039/c5nr07924a. View