Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination

Overview
Date 2021 Jun 2
PMID 34072067
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Extracorporeal carbon dioxide removal (ECCOR) is an important technique to treat critical lung diseases such as exacerbated chronic obstructive pulmonary disease (COPD) and mild or moderate acute respiratory distress syndrome (ARDS). This study applies our previously presented ECCOR mock circuit to compare the CO removal capacity of circular versus parallel-plated membrane lungs at different sweep gas flow rates (0.5, 2, 4, 6 L/min) and blood flow rates (0.3 L/min, 0.9 L/min). For both designs, two low-flow polypropylene membrane lungs (Medos Hilte 1000, Quadrox-i Neonatal) and two mid-flow polymethylpentene membrane lungs (Novalung Minilung, Quadrox-iD Pediatric) were compared. While the parallel-plated Quadrox-iD Pediatric achieved the overall highest CO removal rates under medium and high sweep gas flow rates, the two circular membrane lungs performed relatively better at the lowest gas flow rate of 0.5 L/min. The low-flow Hilite 1000, although overall better than the Quadrox i-Neonatal, had the most significant advantage at a gas flow of 0.5 L/min. Moreover, the circular Minilung, despite being significantly less efficient than the Quadrox-iD Pediatric at medium and high sweep gas flow rates, did not show a significantly worse CO removal rate at a gas flow of 0.5 L/min but rather a slight advantage. We suggest that circular membrane lungs have an advantage at low sweep gas flow rates due to reduced shunting as a result of their fiber orientation. Efficiency for such low gas flow scenarios might be relevant for possible future portable ECCOR devices.

Citing Articles

Recent Advances and Future Directions in Extracorporeal Carbon Dioxide Removal.

Lamas T, Fernandes S, Vasques F, Karagiannidis C, Camporota L, Barrett N J Clin Med. 2025; 14(1.

PMID: 39797096 PMC: 11722077. DOI: 10.3390/jcm14010012.


A Novel Mock Circuit to Test Full-Flow Extracorporeal Membrane Oxygenation.

Caspari S, Schwarzel L, Jungmann A, Schmoll N, Seiler F, Muellenbach R Membranes (Basel). 2022; 12(5).

PMID: 35629818 PMC: 9147719. DOI: 10.3390/membranes12050493.

References
1.
Barrett N, Hart N, Camporota L . In-vitro performance of a low flow extracorporeal carbon dioxide removal circuit. Perfusion. 2019; 35(3):227-235. DOI: 10.1177/0267659119865115. View

2.
Rambaud J, Guilbert J, Guellec I, Renolleau S . A pilot study comparing two polymethylpentene extracorporeal membrane oxygenators. Perfusion. 2012; 28(1):14-20. DOI: 10.1177/0267659112457970. View

3.
Hospach I, Goldstein J, Harenski K, Laffey J, Pouchoulin D, Raible M . In vitro characterization of PrismaLung+: a novel ECCOR device. Intensive Care Med Exp. 2020; 8(1):14. PMC: 7221037. DOI: 10.1186/s40635-020-00301-7. View

4.
May A, Jeffries R, Frankowski B, Burgreen G, Federspiel W . Bench Validation of a Compact Low-Flow CO Removal Device. Intensive Care Med Exp. 2018; 6(1):34. PMC: 6153260. DOI: 10.1186/s40635-018-0200-7. View

5.
Khan S, Vasavada R, Qiu F, Kunselman A, Undar A . Extracorporeal life support systems: alternative vs. conventional circuits. Perfusion. 2011; 26(3):191-8. DOI: 10.1177/0267659110395060. View