» Articles » PMID: 34069108

Stretchable Capacitive Pressure Sensing Sleeve Deployable Onto Catheter Balloons Towards Continuous Intra-Abdominal Pressure Monitoring

Overview
Specialty Biotechnology
Date 2021 Jun 2
PMID 34069108
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Intra-abdominal pressure (IAP) is closely correlated with intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) diagnoses, indicating the need for continuous monitoring. Early intervention for IAH and ACS has been proven to reduce the rate of morbidity. However, the current IAP monitoring method is a tedious process with a long calibration time for a single time point measurement. Thus, there is the need for an efficient and continuous way of measuring IAP. Herein, a stretchable capacitive pressure sensor with controlled microstructures embedded into a cylindrical elastomeric mold, fabricated as a pressure sensing sleeve, is presented. The sensing sleeve can be readily deployed onto intrabody catheter balloons for pressure measurement at the site. The thin and highly conformable nature of the pressure sensing sleeve captures the pressure change without hindering the functionality of the foley catheter balloon.

Citing Articles

Validation of continuous intraabdominal pressure measurement: feasibility and accuracy assessment using a capsular device in in-vivo studies.

Ho D, Cheng C, Ouyang C, Lin W, Liao C World J Emerg Surg. 2024; 19(1):25.

PMID: 38926694 PMC: 11201848. DOI: 10.1186/s13017-024-00553-8.


A Review of Recent Advancements in Sensor-Integrated Medical Tools.

Park J, Seo B, Jeong Y, Park I Adv Sci (Weinh). 2024; 11(20):e2307427.

PMID: 38460177 PMC: 11132050. DOI: 10.1002/advs.202307427.


Biomimetic Exogenous "Tissue Batteries" as Artificial Power Sources for Implantable Bioelectronic Devices Manufacturing.

Yue O, Wang X, Xie L, Bai Z, Zou X, Liu X Adv Sci (Weinh). 2024; 11(11):e2307369.

PMID: 38196276 PMC: 10953594. DOI: 10.1002/advs.202307369.


Frontiers of Wearable Biosensors for Human Health Monitoring.

Xian X Biosensors (Basel). 2023; 13(11).

PMID: 37998139 PMC: 10669529. DOI: 10.3390/bios13110964.


Evaluation of the TraumaGuard Balloon-in-Balloon Catheter Design for Intra-Abdominal Pressure Monitoring: Insights from Pig and Human Cadaver Studies.

Tayebi S, McKinney T, McKinney C, Delvadia D, Levine M, Spofford Jr E Sensors (Basel). 2023; 23(21).

PMID: 37960507 PMC: 10650764. DOI: 10.3390/s23218806.


References
1.
Booth J, Shah D, Case J, White E, Yuen M, Cyr-Choiniere O . OmniSkins: Robotic skins that turn inanimate objects into multifunctional robots. Sci Robot. 2020; 3(22). DOI: 10.1126/scirobotics.aat1853. View

2.
Han M, Chen L, Aras K, Liang C, Chen X, Zhao H . Catheter-integrated soft multilayer electronic arrays for multiplexed sensing and actuation during cardiac surgery. Nat Biomed Eng. 2020; 4(10):997-1009. PMC: 8021456. DOI: 10.1038/s41551-020-00604-w. View

3.
Hunt L, Frost S, Hillman K, Newton P, Davidson P . Management of intra-abdominal hypertension and abdominal compartment syndrome: a review. J Trauma Manag Outcomes. 2014; 8(1):2. PMC: 3925290. DOI: 10.1186/1752-2897-8-2. View

4.
Ribeiro Junior M, Feng C, Nguyen A, Rodrigues V, Bechara G, de-Moura R . The complications associated with Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA). World J Emerg Surg. 2018; 13:20. PMC: 5948672. DOI: 10.1186/s13017-018-0181-6. View

5.
Gao Y, Ota H, Schaler E, Chen K, Zhao A, Gao W . Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring. Adv Mater. 2017; 29(39). DOI: 10.1002/adma.201701985. View