» Articles » PMID: 34056258

Development of a Sensitive Headspace Gas Chromatography-Mass Spectrometry Method for the Simultaneous Determination of Nitrosamines in Losartan Active Pharmaceutical Ingredients

Overview
Journal ACS Omega
Specialty Chemistry
Date 2021 May 31
PMID 34056258
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Nitrosamine impurities in angiotensin II receptor antagonists (sartans) containing a tetrazole group represent an urgent concern for active pharmaceutical ingredient (API) manufacturers and global regulators. Regarding safety, API manufacturers must develop methods to monitor the levels of each nitrosamine impurity before individual batch release. In this study, we developed and validated a sensitive, selective, and high-throughput method based on headspace gas chromatography-mass spectrometry (HS-GC-MS) for the simultaneous determination of four nitrosamines in losartan potassium API with simple sample preparation. -Nitrosodimethylamine (NDMA, 74), -nitrosodiethylamine (NDEA, 102), -nitrosoethylisopropylamine (EIPNA, 116), and -nitrosodiisopropylamine (DIPNA, 130) levels were quantified using an electron impact, single quadrupole mass spectrometer under a selected-ion-monitoring acquisition method. The method was validated according to the Q2(R1) ICH guidelines. The calibration curves of the assay ranged from 25 to 5000 ng/mL with limits of quantitation of 25 ppb for NDMA and NDEA and 50 ppb for DIPNA and EIPNA. The accuracy of the developed method ranged from -7.04% to 7.25%, and the precision %CV was ≤11.5. Other validation parameters, including specificity, stability, carryover, and robustness, met the validation criteria. In conclusion, the developed method was successfully applied for the determination of nitrosamines in losartan potassium APIs.

Citing Articles

Development of a green-synthesized molecularly imprinted polymer-based electrochemical nanosensor for the determination of N-nitrosodimethylamine (NDMA) in serum and tap water.

Jadon N, Cetinkaya A, Ozcelikay-Akyildiz G, Kaya S, Bellur Atici E, Uzun L Mikrochim Acta. 2024; 191(12):769.

PMID: 39609307 DOI: 10.1007/s00604-024-06850-y.


Nitrosamines crisis in pharmaceuticals - Insights on toxicological implications, root causes and risk assessment: A systematic review.

Vikram H, Kumar T, Kumar G, Beeraka N, Deka R, Suhail S J Pharm Anal. 2024; 14(5):100919.

PMID: 38799236 PMC: 11126534. DOI: 10.1016/j.jpha.2023.12.009.


Development and Validation of LC-MS/MS Method for the Determination of 1-Methyl-4-Nitrosopiperazine (MNP) in Multicomponent Products with Rifampicin-Analytical Challenges and Degradation Studies.

Witkowska A, Wolczynska A, Lis-Cieplak A, Stolarczyk E Molecules. 2023; 28(21).

PMID: 37959824 PMC: 10648194. DOI: 10.3390/molecules28217405.


Development of a Sensitive Screening Method for Simultaneous Determination of Nine Genotoxic Nitrosamines in Active Pharmaceutical Ingredients by GC-MS.

Witkowska A, Giebultowicz J, Dabrowska M, Stolarczyk E Int J Mol Sci. 2022; 23(20).

PMID: 36292981 PMC: 9603764. DOI: 10.3390/ijms232012125.


Cost-effective, green HPLC determination of losartan, valsartan and their nitrosodiethylamine impurity: application to pharmaceutical dosage forms.

Abd El-Hay S, Elhenawee M, Maged K, Ibrahim A R Soc Open Sci. 2022; 9(6):220250.

PMID: 35706671 PMC: 9156911. DOI: 10.1098/rsos.220250.


References
1.
Parr M, Joseph J . NDMA impurity in valsartan and other pharmaceutical products: Analytical methods for the determination of N-nitrosamines. J Pharm Biomed Anal. 2018; 164:536-549. DOI: 10.1016/j.jpba.2018.11.010. View

2.
Byrd J, Chertow G, Bhalla V . Hypertension Hot Potato - Anatomy of the Angiotensin-Receptor Blocker Recalls. N Engl J Med. 2019; 380(17):1589-1591. PMC: 7066505. DOI: 10.1056/NEJMp1901657. View

3.
Barreras A, Gurk-Turner C . Angiotensin II receptor blockers. Proc (Bayl Univ Med Cent). 2005; 16(1):123-6. PMC: 1200815. DOI: 10.1080/08998280.2003.11927893. View

4.
Burnier M, Brunner H . Angiotensin II receptor antagonists. Lancet. 2000; 355(9204):637-45. DOI: 10.1016/s0140-6736(99)10365-9. View

5.
Chang S, Chang C, Wang L, Chen W, Fan S, Zang C . A multi-analyte LC-MS/MS method for screening and quantification of nitrosamines in sartans. J Food Drug Anal. 2022; 28(2):292-301. PMC: 9261856. DOI: 10.38212/2224-6614.1063. View