» Articles » PMID: 33971277

Expert Consensus Statement from the American Society of Echocardiography on Hypersensitivity Reactions to Ultrasound Enhancing Agents in Patients with Allergy to Polyethylene Glycol

Overview
Specialty Radiology
Date 2021 May 10
PMID 33971277
Citations 10
Authors
Affiliations
Soon will be listed here.
Citing Articles

Multi-societal expert consensus statement on the safe administration of ultrasound contrast agents.

Strom J, Appis A, Barr R, Chammas M, Clevert D, Darge K Echo Res Pract. 2025; 12(1):4.

PMID: 39985014 PMC: 11846211. DOI: 10.1186/s44156-024-00068-7.


Comments and Illustrations of the European Federation of Societies for Ultrasound in Medicine (EFSUMB) Guidelines: Rare Malignant Pulmonal and Pleural Tumors: Primary Pulmonary Sarcoma and Mesothelioma, Imaging Features on Transthoracic Ultrasound.

Moller K, Dietz F, Ludwig M, Eisenmann S, Gorg C, Safai Zadeh E Diagnostics (Basel). 2024; 14(20).

PMID: 39451662 PMC: 11506974. DOI: 10.3390/diagnostics14202339.


Evaluation of left ventricular function and volume by two-dimensional echocardiography in a pediatric population: Correlation with cardiac magnetic resonance imaging.

Bhansali S, Tokar E, Saharan S, Khalil R, Bhatla P Ann Pediatr Cardiol. 2024; 17(1):28-35.

PMID: 38933052 PMC: 11198934. DOI: 10.4103/apc.apc_199_23.


Intravenous administration of ultrasound contrast to critically ill pediatric patients.

Riggs B, Martinez-Correa S, Stern J, Tierradentro-Garcia L, Haddad S, Anupindi S Pediatr Radiol. 2024; 54(5):820-830.

PMID: 38506945 PMC: 11562664. DOI: 10.1007/s00247-024-05898-5.


A retrospective study on adverse events of intravenous administration of sulfur hexafluoride microbubbles in abdominal and superficial applications in 83,778 patients.

Li D, Zhang R, Lan H, Chen M, Huang Z, Zhao H Insights Imaging. 2024; 15(1):65.

PMID: 38411872 PMC: 10899544. DOI: 10.1186/s13244-024-01632-9.


References
1.
Stone Jr C, Liu Y, Relling M, Krantz M, Pratt A, Abreo A . Immediate Hypersensitivity to Polyethylene Glycols and Polysorbates: More Common Than We Have Recognized. J Allergy Clin Immunol Pract. 2018; 7(5):1533-1540.e8. PMC: 6706272. DOI: 10.1016/j.jaip.2018.12.003. View

2.
Muskula P, Main M . Safety With Echocardiographic Contrast Agents. Circ Cardiovasc Imaging. 2017; 10(4). DOI: 10.1161/CIRCIMAGING.116.005459. View

3.
Wei K, Mulvagh S, Carson L, Davidoff R, Gabriel R, Grimm R . The safety of deFinity and Optison for ultrasound image enhancement: a retrospective analysis of 78,383 administered contrast doses. J Am Soc Echocardiogr. 2008; 21(11):1202-6. DOI: 10.1016/j.echo.2008.07.019. View

4.
Main M, Hibberd M, Ryan A, Lowe T, Miller P, Bhat G . Acute mortality in critically ill patients undergoing echocardiography with or without an ultrasound contrast agent. JACC Cardiovasc Imaging. 2013; 7(1):40-8. DOI: 10.1016/j.jcmg.2013.08.012. View

5.
Sellaturay P, Nasser S, Ewan P . Polyethylene Glycol-Induced Systemic Allergic Reactions (Anaphylaxis). J Allergy Clin Immunol Pract. 2020; 9(2):670-675. DOI: 10.1016/j.jaip.2020.09.029. View