Reproducibility of Ambulatory Oesophageal PH Monitoring

Overview
Journal Gut
Specialty Gastroenterology
Date 1988 Jul 1
PMID 3396963
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

To evaluate the reproducibility of ambulatory 24 hour intraoesophageal pH monitoring, 20 patients were randomly selected to undergo two consecutive investigations. Fifteen patients were classified as either abnormal, or normal on both test days. The amount of acid reflux, expressed as percentage of time with oesophageal pH below 4.0 during the two 24 hour periods, showed 77% concordance. The upright and recumbent periods of measurement showed different degrees of concordance: 83% and 62%, respectively. The reproducibility during time periods of different length was found to increase with increasing length of day time pH recording. A 16 hour period during evening and night had a reproducibility of only 58%, however. It is concluded that there is fairly good reproducibility when measuring gastro-oesophageal reflux over 24 hours, but that the reproducibility is poorer at night, during the postprandial period and when daytime monitoring is shorter than 10 hours.

Citing Articles

British Society of Gastroenterology guidelines for oesophageal manometry and oesophageal reflux monitoring.

Trudgill N, Sifrim D, Sweis R, Fullard M, Basu K, McCord M Gut. 2019; 68(10):1731-1750.

PMID: 31366456 PMC: 6839728. DOI: 10.1136/gutjnl-2018-318115.


Yield of prolonged wireless pH monitoring in achalasia patients successfully treated with pneumatic dilation.

Mauro A, Franchina M, Elvevi A, Pugliese D, Tenca A, Conte D United European Gastroenterol J. 2017; 5(6):789-795.

PMID: 29026592 PMC: 5625868. DOI: 10.1177/2050640616681366.


Gastroesophageal Reflux Disease: A Population Based Study.

Nwokediuko S Gastroenterology Res. 2016; 2(3):152-156.

PMID: 27933125 PMC: 5139706. DOI: 10.4021/gr2009.05.1291.


More art than science: impedance analysis prone to interpretation error.

Ciecierega T, Gordon B, Aronova A, Crawford C, Zarnegar R J Gastrointest Surg. 2015; 19(6):987-92.

PMID: 25876531 DOI: 10.1007/s11605-015-2809-0.


Inconsistency in the Diagnosis of Functional Heartburn: Usefulness of Prolonged Wireless pH Monitoring in Patients With Proton Pump Inhibitor Refractory Gastroesophageal Reflux Disease.

Penagini R, Sweis R, Mauro A, Domingues G, Vales A, Sifrim D J Neurogastroenterol Motil. 2015; 21(2):265-72.

PMID: 25843078 PMC: 4398246. DOI: 10.5056/jnm14075.


References
1.
Stanciu C, Bennett J . Alginate-antacid in the reduction of gastro-oesophageal reflux. Lancet. 1974; 1(7848):109-11. DOI: 10.1016/s0140-6736(74)92340-x. View

2.
Johnsson F, Joelsson B, Isberg P . Ambulatory 24 hour intraesophageal pH-monitoring in the diagnosis of gastroesophageal reflux disease. Gut. 1987; 28(9):1145-50. PMC: 1433234. DOI: 10.1136/gut.28.9.1145. View

3.
DeMeester T, Johnson L, Joseph G, Toscano M, Hall A, SKINNER D . Patterns of gastroesophageal reflux in health and disease. Ann Surg. 1976; 184(4):459-70. PMC: 1345443. DOI: 10.1097/00000658-197610000-00009. View

4.
Boesby S . Continuous oesophageal pH recording and acid-clearing test. A study of reproducibility. Scand J Gastroenterol. 1977; 12(2):245-7. View

5.
Atkinson M, van Gelder A . Esophageal intraluminal pH recording in the assessment of gastroesophageal reflux and its consequences. Am J Dig Dis. 1977; 22(4):365-70. DOI: 10.1007/BF01072195. View