» Articles » PMID: 33953610

Study on the Appropriate Timing of Postoperative Adaptive Radiotherapy for High-Grade Glioma

Overview
Publisher Dove Medical Press
Specialty Oncology
Date 2021 May 6
PMID 33953610
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the appropriate timing of adaptive radiotherapy (ART) for high-grade glioma.

Methods: Ten patients with high-grade gliomas were selected and underwent CT/MRI (CT/MRI, CT/MRI, CT/MRI, and CT/MRI) scans before RT and during 10-, 20- and 30-fraction RT, and the corresponding RT plans (plan, plan, plan and plan) were made. The dose of the initial plan (plan) was projected to CT2 and CT3 using the image registration technique to obtain the projection plans (plan and plan) and by superimposing the doses to obtain the ART plans (plan and plan), respectively. The dosimetric differences in the target volume and organs at risk (OARs) were compared between the projection and adaptive plans. The tumor control probability (TCP) for the planning target volume (PTV) and normal tissue complication probability (NTCP) for the OARs were compared between the two adaptive plans.

Results: Compared with the projection plan, the D to the PTV of ART decreased, the conformity index (CI) to the PTV increased, and the D/D to the brainstem, optic chiasm and pituitary, as well as the V, V, V and V to the normal brain decreased. The D to the pituitary and optic chiasm as well as the V, V, V and V to the normal brain in plan were lower than those in plan, while the CI to the PTV was higher than that in plan. The TCP of the PTV in plan was higher than that in plan.

Conclusion: ART can improve the precision of target volume irradiation and reduce the irradiation dose to the OARs in high-grade glioma. The time point after 10 fractions of RT is appropriate for ART.

Citing Articles

Radiotherapy of High-Grade Gliomas: First Half of 2021 Update with Special Reference to Radiosensitization Studies.

Frosina G Int J Mol Sci. 2021; 22(16).

PMID: 34445646 PMC: 8396323. DOI: 10.3390/ijms22168942.

References
1.
Paddick I . A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note. J Neurosurg. 2001; 93 Suppl 3:219-22. DOI: 10.3171/jns.2000.93.supplement. View

2.
Ruben J, Dally M, Bailey M, Smith R, McLean C, Fedele P . Cerebral radiation necrosis: incidence, outcomes, and risk factors with emphasis on radiation parameters and chemotherapy. Int J Radiat Oncol Biol Phys. 2006; 65(2):499-508. DOI: 10.1016/j.ijrobp.2005.12.002. View

3.
Burman C, Kutcher G, Emami B, Goitein M . Fitting of normal tissue tolerance data to an analytic function. Int J Radiat Oncol Biol Phys. 1991; 21(1):123-35. DOI: 10.1016/0360-3016(91)90172-z. View

4.
Yang Z, Zhang Z, Wang X, Hu Y, Lyu Z, Huo L . Intensity-modulated radiotherapy for gliomas:dosimetric effects of changes in gross tumor volume on organs at risk and healthy brain tissue. Onco Targets Ther. 2016; 9:3545-54. PMC: 4914054. DOI: 10.2147/OTT.S100455. View

5.
Tsien C, Brown D, Normolle D, Schipper M, Piert M, Junck L . Concurrent temozolomide and dose-escalated intensity-modulated radiation therapy in newly diagnosed glioblastoma. Clin Cancer Res. 2011; 18(1):273-9. PMC: 3266840. DOI: 10.1158/1078-0432.CCR-11-2073. View