ISO 4049 Versus NIST 4877: Influence of Stress Configuration on the Outcome of a Three-point Bending Test in Resin-based Dental Materials and Interrelation Between Standards
Overview
Authors
Affiliations
Objectives: The study aimed to find a relationship between the most common standards used in testing resin-based materials (RBC) in a three-point bend test - ISO 4049 and NIST 4877 - using a size-strength relationship defined by the Weibull model. The direct comparison of calculated and measured data is used for validation.
Methods: 280 (n = 20) specimens were prepared from seven different light-cured RBCs. The flexural strength, FS, and modulus, E, were measured with a span of 12 mm (NIST) or 20 mm (ISO). A fractographic analysis determined the origin of fracture. One and multiple-way analysis of variance (ANOVA), the Tukey honestly significant difference (HSD) post-hoc tests (α = 0.05), Weibull statistics and Pearson correlation analysis were used for data analysis.
Results: Calculated data approximate the measured data very well. FS measured according to ISO is 11 % lower and E is 17 % higher than the NIST data. The test method influenced the properties measured, but not the material ranking or the fracture mode. Fractures originated from volume defects (sub-surface) were the most common type of fracture.
Conclusions: Weibull analysis is successful to predict the scaling of strengths to other configurations in RBCs.
Clinical Significance: The need to limit the sample size of RBCs up to the dimensions of their clinical use can benefit from the use of Weibull statistics. Weibull size-strength relationship and fractographic analysis can help to better assess the clinical behaviour of the RBCs, calculate the reliability of a restoration, and assess the nature of the flaws in the material.
Ilie N Nanomaterials (Basel). 2025; 15(1.
PMID: 39791832 PMC: 11723379. DOI: 10.3390/nano15010074.
Batu Eken Z, Ilie N Materials (Basel). 2024; 17(19).
PMID: 39410424 PMC: 11478171. DOI: 10.3390/ma17194853.
Al-Zain A, Piva E, Pimentel A, Duarte C, Valente L, Isolan C Braz Oral Res. 2024; 38:e062.
PMID: 39016368 PMC: 11376674. DOI: 10.1590/1807-3107bor-2024.vol38.0062.
Mandic V, Plancak L, Marovic D, Tarle Z, Trutina Gavran M, Par M Materials (Basel). 2024; 17(11).
PMID: 38894041 PMC: 11173928. DOI: 10.3390/ma17112777.
[Light-curing effectiveness using led lamps: a review].
Aquino Valverde A, Aguilar Vargas G, Diaz Fernandez J, Leiva Ramirez P, Quintanilla Labajos D, Atoche Socola K Rev Cient Odontol (Lima). 2024; 10(3):e120.
PMID: 38389554 PMC: 10880699. DOI: 10.21142/2523-2754-1003-2022-120.