Abstract

Purpose: If substitution of the posterior cruciate ligament in total knee arthroplasty is necessary, there are two options available: posterior stabilized (PS) design with a post-cam mechanism or anterior-lipped ultracongruent (UC) inserts. UC inserts have the advantage that no femoral box is necessary and a standard femoral component can be used. The aim of this study was to compare the range of motion (ROM) and patient-reported outcome (PRO) after UC and PS fixed-bearing TKA. Better ROM in PS TKA and no difference in PRO between both designs was hypothesized.

Methods: A randomized controlled trial with 127 patients receiving a fixed-bearing UC or PS design of the same knee system was performed. Nine patients died and there were four revision surgeries. 107 patients completed the 5-year follow-up. Patient-reported outcome was assessed. Patellofemoral problems were evaluated using selected applicable questions of the Oxford Knee Score (getting up from a table, kneeling, climbing stairs).

Results: Surgical time was 10 min shorter in the UC group (p < 0.001). After 5 years, both groups demonstrated good knee function and health-related quality of life without significant differences between the groups. Both groups demonstrated a high satisfaction score and the majority of patients would undergo this surgery again. Patellofemoral problems were recognized more frequently in the PS group (p = 0.025).

Conclusion: Both designs demonstrated similar good results after 5 years. Stabilization with an anterior-lipped UC insert can be considered a safe alternative to the well-established PS design if cruciate substitution is necessary.

Level Of Evidence: 1:

Citing Articles

Patient Reported Outcomes of Total Knee Arthroplasty with Ultra-congruent Lipped Polyethylene Liners: A Randomized Study.

Liu J, Daher M, Laperche J, Clippert D, Ibrahim Z, Barrett T Arch Bone Jt Surg. 2025; 13(2):100-105.

PMID: 39980802 PMC: 11836800. DOI: 10.22038/ABJS.2024.80407.3674.


Kinematic Patterns of Different Loading Profiles Before and After Total Knee Arthroplasty: A Cadaveric Study.

Brendle S, Krueger S, Fehrenbacher J, Grifka J, Muller P, Mihalko W Bioengineering (Basel). 2024; 11(11).

PMID: 39593724 PMC: 11591247. DOI: 10.3390/bioengineering11111064.


No difference in patient-reported outcomes or range of motion between ultracongruent and posterior stabilized total knee arthroplasty: A randomized controlled trial.

Macedo F, Lucas J, Cunha P, Rocha M, Cerqueira R, Basto T J Exp Orthop. 2024; 11(4):e70043.

PMID: 39435297 PMC: 11491980. DOI: 10.1002/jeo2.70043.


A New Methodology for the Accurate Measurement of Tibiofemoral Kinematics in Human Cadaveric Knees: An Evaluation of the Anterior-Posterior Laxity Pre- and Post-Cruciate Ligament Resection.

Brendle S, Krueger S, Grifka J, Muller P, Grupp T Life (Basel). 2024; 14(7).

PMID: 39063630 PMC: 11278153. DOI: 10.3390/life14070877.


The Effect of Congruent Tibial Inserts in Total Knee Arthroplasty: A Network Meta-Analysis of Randomized Controlled Trials.

Tsai Y, Tsai S, Lin C, Lin C, Hu C Life (Basel). 2023; 13(9).

PMID: 37763345 PMC: 10532924. DOI: 10.3390/life13091942.


References
1.
Akti S, Karakus D, Sezgin E, Cankaya D . No differences in clinical outcomes or isokinetic performance between cruciate-substituting ultra-congruent and posterior stabilized total knee arthroplasties: a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc. 2020; 29(10):3443-3449. DOI: 10.1007/s00167-020-06275-z. View