The Left Ventricular Assist Device As a Patient Monitoring System

Overview
Date 2021 Apr 12
PMID 33842216
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Technological progress of left ventricular assist devices (LVADs) towards rotary blood pumps and the optimization of medical management contributed to the significant improvements in patient survival as well as LVAD support duration. Even though LVAD therapy is now well-established for end-stage heart failure patients, the long-term occurrence of adverse events (AE) such as bleeding, infection or stroke, still represent a relevant burden. An early detection of AE, before onset of major symptoms, can lead to further optimization of patient treatment and thus mitigate the burden of AE. Continuous patient monitoring facilitates identification of pathophysiological states and allows anticipation of AE to improve patient management. In this paper, methods, algorithms and possibilities for continuous patient monitoring based on LVAD data are reviewed. While experience with continuous LVAD monitoring is currently limited to a few centers worldwide, the pace of developments in this field is fast and we expect these technologies to have a global impact on the well-being of LVAD patients.

Citing Articles

An model to study suction events by a ventricular assist device: validation with clinical data.

Rocchi M, Gross C, Moscato F, Schloglhofer T, Meyns B, Fresiello L Front Physiol. 2023; 14:1155032.

PMID: 37560156 PMC: 10407082. DOI: 10.3389/fphys.2023.1155032.


Initial clinical validation of a hybrid - cardiorespiratory simulator for comprehensive testing of mechanical circulatory support systems.

Fresiello L, Muthiah K, Goetschalckx K, Hayward C, Rocchi M, Bezy M Front Physiol. 2022; 13:967449.

PMID: 36311247 PMC: 9606213. DOI: 10.3389/fphys.2022.967449.

References
1.
Hayward C, Lim C, Schima H, Macdonald P, Moscato F, Muthiah K . Pump Speed Waveform Analysis to Detect Aortic Valve Opening in Patients on Ventricular Assist Device Support. Artif Organs. 2015; 39(8):704-9. DOI: 10.1111/aor.12570. View

2.
Granegger M, Schloglhofer T, Ober H, Zimpfer D, Schima H, Moscato F . Daily life activity in patients with left ventricular assist devices. Int J Artif Organs. 2016; 39(1):22-7. PMC: 6122587. DOI: 10.5301/ijao.5000464. View

3.
Orihashi K, Hong Y, Chung G, Sisto D, Goldiner P, Oka Y . New applications of two-dimensional transesophageal echocardiography in cardiac surgery. J Cardiothorac Vasc Anesth. 1991; 5(1):33-9. DOI: 10.1016/1053-0770(91)90090-g. View

4.
AlHarbi M, Straiton N, Gallagher R . Harnessing the Potential of Wearable Activity Trackers for Heart Failure Self-Care. Curr Heart Fail Rep. 2017; 14(1):23-29. DOI: 10.1007/s11897-017-0318-z. View

5.
Bunge J, den Uil C, Constantinescu A, Budde R, Maat A, Caliskan K . Acute Pump Thrombosis in the Early Postoperative Period After HeartMate 3 Implantation. ASAIO J. 2019; 65(7):e72-e74. DOI: 10.1097/MAT.0000000000000932. View