Objectives: To evaluate the potential of a fully automatic artificial intelligence (AI)-driven computed tomography (CT) software prototype to quantify severity of COVID-19 infection on chest CT in relationship with clinical and laboratory data.
Methods: We retrospectively analyzed 50 patients with laboratory confirmed COVID-19 infection who had received chest CT between March and July 2020. Pulmonary opacifications were automatically evaluated by an AI-driven software and correlated with clinical and laboratory parameters using Spearman-Rho and linear regression analysis. We divided the patients into sub cohorts with or without necessity of intensive care unit (ICU) treatment. Sub cohort differences were evaluated employing Wilcoxon-Mann-Whitney-Test.
Results: We included 50 CT examinations (mean age, 57.24 years), of whom 24 (48%) had an ICU stay. Extent of COVID-19 like opacities on chest CT showed correlations (all p < 0.001 if not otherwise stated) with occurrence of ICU stay (R = 0.74), length of ICU stay (R = 0.81), lethal outcome (R = 0.56) and length of hospital stay (R = 0.33, p < 0.05). The opacities extent was correlated with laboratory parameters: neutrophil count (NEU) (R = 0.60), lactate dehydrogenase (LDH) (R = 0.60), troponin (TNTHS) (R = 0.55) and c-reactive protein (CRP) (R = 0.51). Differences (p < 0.001) between ICU group and non-ICU group concerned longer length of hospital stay (24.04 vs. 10.92 days), higher opacity score (12.50 vs. 4.96) and severity of laboratory data changes such as c-reactive protein (11.64 vs. 5.07 mg/dl, p < 0.01).
Conclusions: Automatically AI-driven quantification of opacities on chest CT correlates with laboratory and clinical data in patients with confirmed COVID-19 infection and may serve as non-invasive predictive marker for clinical course of COVID-19.
Chauvot de Beauchene R, Souweine B, Bonnet B, Evrard B, Boirie Y, Cassagnes L Sci Rep. 2025; 15(1):4373.
PMID: 39910127 PMC: 11799377. DOI: 10.1038/s41598-025-88914-4.
Krisht A, Grapin K, Chauvot de Beauchene R, Bonnet B, Cassagnes L, Evrard B PLoS One. 2024; 19(9):e0308014.
PMID: 39298399 PMC: 11412649. DOI: 10.1371/journal.pone.0308014.
Vasquez-Venegas C, Sotomayor C, Ramos B, Castaneda V, Pereira G, Cabrera-Vives G J Clin Med. 2024; 13(17).
PMID: 39274444 PMC: 11396404. DOI: 10.3390/jcm13175231.
Detection method of viral pneumonia imaging features based on CT scan images in COVID-19 case study.
Hermawati F, Trilaksono B, Nugroho A, Imah E, Lukas , Kamelia T MethodsX. 2024; 12:102507.
PMID: 38204979 PMC: 10776984. DOI: 10.1016/j.mex.2023.102507.
Tanaka H, Maetani T, Chubachi S, Tanabe N, Shiraishi Y, Asakura T Respir Res. 2023; 24(1):241.
PMID: 37798709 PMC: 10552312. DOI: 10.1186/s12931-023-02530-2.