» Articles » PMID: 33728104

Sputum Processing Method for Lateral Flow Immunochromatographic Assays to Detect Coronaviruses

Overview
Journal Immune Netw
Date 2021 Mar 17
PMID 33728104
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Coronavirus causes an infectious disease in various species and crosses the species barriers leading to the outbreak of zoonotic diseases. Due to the respiratory diseases are mainly caused in humans and viruses are replicated and excreted through the respiratory tract, the nasal fluid and sputum are mainly used for diagnosis. Early diagnosis of coronavirus plays an important role in preventing its spread and is essential for quarantine policies. For rapid decision and prompt triage of infected host, the immunochromatographic assay (ICA) has been widely used for point of care testing. However, when the ICA is applied to an expectorated sputum in which antigens are present, the viscosity of sputum interferes with the migration of the antigens on the test strip. To overcome this limitation, it is necessary to use a mucolytic agent without affecting the antigens. In this study, we combined known mucolytic agents to lower the viscosity of sputum and applied that to alpha and beta coronavirus, porcine epidemic diarrhea virus (PEDV) and Middle East respiratory syndrome coronavirus (MERS-CoV), respectively, spiked in sputum to find optimal pretreatment conditions. The pretreatment method using tris(2-carboxyethyl)phosphine (TCEP) and BSA was suitable for ICA diagnosis of sputum samples spiked with PEDV and MERS-CoV. This sensitive assay for the detection of coronavirus in sputum provides an useful information for the diagnosis of pathogen in low respiratory tract.

Citing Articles

Advances in porcine epidemic diarrhea virus research: genome, epidemiology, vaccines, and detection methods.

Zhuang L, Zhao Y, Shen J, Sun L, Hao P, Yang J Discov Nano. 2025; 20(1):48.

PMID: 40029472 PMC: 11876513. DOI: 10.1186/s11671-025-04220-y.


A portable transistor immunosensor for fast identification of porcine epidemic diarrhea virus.

Hu X, Zhang M, Liu Y, Li Y, Li W, Li T J Nanobiotechnology. 2024; 22(1):239.

PMID: 38735951 PMC: 11089749. DOI: 10.1186/s12951-024-02440-5.


Direct Detection of Feline Coronavirus by Three Rapid Antigen Immunochromatographic Tests and by Real-Time PCR in Cat Shelters.

Vojtkovska V, Lukesova G, Voslarova E, Konvalinova J, Vecerek V, Lobova D Vet Sci. 2022; 9(2).

PMID: 35202289 PMC: 8875548. DOI: 10.3390/vetsci9020035.

References
1.
Li H, Han D, Hegener M, Pauletti G, Steckl A . Flow reproducibility of whole blood and other bodily fluids in simplified no reaction lateral flow assay devices. Biomicrofluidics. 2017; 11(2):024116. PMC: 5533494. DOI: 10.1063/1.4979815. View

2.
Song D, Ha G, Serhan W, Eltahir Y, Yusof M, Hashem F . Development and validation of a rapid immunochromatographic assay for detection of Middle East respiratory syndrome coronavirus antigen in dromedary camels. J Clin Microbiol. 2015; 53(4):1178-82. PMC: 4365254. DOI: 10.1128/JCM.03096-14. View

3.
Carlson T, Lock J, Carrier R . Engineering the Mucus Barrier. Annu Rev Biomed Eng. 2018; 20:197-220. PMC: 6463277. DOI: 10.1146/annurev-bioeng-062117-121156. View

4.
Chen Y, Chan K, Kang Y, Chen H, Luk H, Poon R . A sensitive and specific antigen detection assay for Middle East respiratory syndrome coronavirus. Emerg Microbes Infect. 2015; 4(4):e26. PMC: 4575394. DOI: 10.1038/emi.2015.26. View

5.
Huang P, Wang H, Cao Z, Jin H, Chi H, Zhao J . A Rapid and Specific Assay for the Detection of MERS-CoV. Front Microbiol. 2018; 9:1101. PMC: 5987675. DOI: 10.3389/fmicb.2018.01101. View