» Articles » PMID: 3372410

Reliability and Validity of Bioelectrical Impedance in Determining Body Composition

Overview
Date 1988 Feb 1
PMID 3372410
Citations 60
Authors
Affiliations
Soon will be listed here.
Abstract

This study was designed to examine the reliability and validity of the bioelectrical impedance method (BIA) of measuring body composition and compare its accuracy with the results obtained by standard anthropometric methods BIA, skinfold fat, and hydrostatically measured percent fat (% fat) were obtained on 44 women and 24 men. Each subject was tested four times by two testers on two different days. Generalizability theory was used to estimate reliability and measurement error that considered both day-to-day and intertester error. The BIA, skinfold fat, and hydrostatic methods were all found to be reliable (Rxx = 0.957-0.987) with standard errors ranging from 0.9 to 1.5% fat. An additional 26 men (n = 50) and 38 women (n = 82) were tested once and combined with the data used for the reliability analysis to cross-validate BIA estimates of % fat with hydrostatically determined % fat. The cross-validation correlations for the BIA determinations of % fat ranged from 0.71 to 0.76, which were significantly lower than that obtained with the sum of seven (sigma 7) skinfolds equations (rxy = 0.92 for men and 0.88 for women). The correlations between the weight-to-height ratio body mass index (BMI) and hydrostatically determined % fat were 0.75 and 0.74 for men and women, respectively. The standard errors of estimate for the two BIA models ranged from 4.6 to 6.4% fat compared with 2.6 and 3.6% fat for the sigma 7 equations. The BIA method for measuring body composition was comparable to the BMI method, with height and weight accounting for most of the variance in the BIA equation.

Citing Articles

Prevalence of sarcopenic obesity: comparison of different diagnostic criteria and exploration of optimal screening methods.

Zhuang M, Wang L, He X, Ma L, Song Y, Chen N BMC Geriatr. 2024; 24(1):799.

PMID: 39350053 PMC: 11443907. DOI: 10.1186/s12877-024-05378-3.


Non-invasive technology to assess hydration status in advanced cancer to explore relationships between fluid status and symptoms: an observational study using bioelectrical impedance analysis.

Nwosu A, Stanley S, Mayland C, Mason S, McDougall A, Ellershaw J BMC Palliat Care. 2024; 23(1):209.

PMID: 39160544 PMC: 11331739. DOI: 10.1186/s12904-024-01542-z.


A screening method for mild cognitive impairment in elderly individuals combining bioimpedance and MMSE.

Jun M, Ku B, Kim K, Lee K, Kim J Front Aging Neurosci. 2024; 16:1307204.

PMID: 38327500 PMC: 10847325. DOI: 10.3389/fnagi.2024.1307204.


Impaired eating behaviors but intact metabolic hormone levels in individuals with major depressive disorder and generalized anxiety disorder.

McNaughton B, Burrows K, Choquette E, Poplin T, Kuplicki R, Paulus M J Psychiatr Res. 2023; 168:193-203.

PMID: 37918032 PMC: 10842703. DOI: 10.1016/j.jpsychires.2023.10.042.


Effects of 8 weeks of resistance training in combination with a high protein diet on body composition, muscular performance, and markers of liver and kidney function in untrained older ex-military men.

Bagheri R, Shakibaee A, Camera D, Sobhani V, Ghobadi H, Nazar E Front Nutr. 2023; 10:1205310.

PMID: 37457969 PMC: 10342203. DOI: 10.3389/fnut.2023.1205310.