» Articles » PMID: 33672531

Determining the Optimal Workrate for Cycle Ergometer Verification Phase Testing in Males with Obesity

Overview
Journal Sports (Basel)
Publisher MDPI
Specialty Public Health
Date 2021 Mar 6
PMID 33672531
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of the present study was to assess the validity of verification phase (VP) testing and a 3 min all-out test to determine critical power (CP) in males with obesity. Nine young adult males with a body mass index (BMI) ≥ 30 kg·m completed a cycle ergometer ramp-style VO test, four randomized VP tests at 80, 90, 100, and 105% of maximum wattage attained during the ramp test, and a 3 min all-out test. There was a significant main effect for VO across all five tests ( = 0.049). Individually, 8 of 9 participants attained a higher VO (L/min) during a VP test compared to the ramp test. A trend ( = 0.06) was observed for VO during the 90% VP test (3.61 ± 0.54 L/min) when compared to the ramp test (3.37 ± 0.39 L/min). A significantly higher VO ( = 0.016) was found in the VP tests that occurred below 130% of CP wattage (N = 15, VO = 3.76 ± 0.52 L/min) compared to those that were above (N = 21, VO = 3.36 ± 0.41 L/min). Our findings suggest submaximal VP tests at 90% may elicit the highest VO in males with obesity and there may be merit in using % of CP wattage to determine optimal VP intensity.

Citing Articles

Confirming the attainment of maximal oxygen uptake within special and clinical groups: A systematic review and meta-analysis of cardiopulmonary exercise test and verification phase protocols.

Costa V, Midgley A, Baumgart J, Carroll S, Astorino T, Schaun G PLoS One. 2024; 19(3):e0299563.

PMID: 38547136 PMC: 10977812. DOI: 10.1371/journal.pone.0299563.


Utility of Verification Testing to Confirm Attainment of Maximal Oxygen Uptake in Unhealthy Participants: A Perspective Review.

Astorino T, Emma D Sports (Basel). 2021; 9(8).

PMID: 34437369 PMC: 8402360. DOI: 10.3390/sports9080108.

References
1.
Moreno-Cabanas A, Ortega J, Morales-Palomo F, Ramirez-Jimenez M, Mora-Rodriguez R . Importance of a verification test to accurately assess V̇O max in unfit individuals with obesity. Scand J Med Sci Sports. 2019; 30(3):583-590. DOI: 10.1111/sms.13602. View

2.
Sanchez-Otero T, Iglesias-Soler E, Boullosa D, Tuimil J . Verification criteria for the determination of Vo2 MAX in the field. J Strength Cond Res. 2014; 28(12):3544-51. DOI: 10.1519/JSC.0000000000000576. View

3.
Hawkins M, Raven P, Snell P, Stray-Gundersen J, Levine B . Maximal oxygen uptake as a parametric measure of cardiorespiratory capacity. Med Sci Sports Exerc. 2007; 39(1):103-7. DOI: 10.1249/01.mss.0000241641.75101.64. View

4.
Mier C, Alexander R, Mageean A . Achievement of VO2max criteria during a continuous graded exercise test and a verification stage performed by college athletes. J Strength Cond Res. 2011; 26(10):2648-54. DOI: 10.1519/JSC.0b013e31823f8de9. View

5.
Wells J, Fewtrell M . Measuring body composition. Arch Dis Child. 2006; 91(7):612-7. PMC: 2082845. DOI: 10.1136/adc.2005.085522. View