» Articles » PMID: 33668884

Development of an In Vitro Blink Model for Ophthalmic Drug Delivery

Overview
Journal Pharmaceutics
Publisher MDPI
Date 2021 Mar 6
PMID 33668884
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The purpose of this study was to develop an advanced in vitro blink model that can be used to examine the release of a wide variety of components (for example, topical ophthalmic drugs, comfort-inducing agents) from soft contact lenses.

Methods: The model was designed using computer-aided design software and printed using a stereolithography 3D printer. The eyelid and eyeball were synthesized from polyvinyl alcohol and silicone material, respectively. Simulated tear fluid was infused through tubing attached to the eyelid using a syringe pump. With each blink cycle, the eyelid slides and flexes across the eyeball to create an artificial tear film layer. The flow-through fluid was collected using a specialized trough. Two contact lenses, etafilcon A and senofilcon A, were incubated in 2 mL of a water-soluble red dye for 24 h and then placed on the eye model ( = 3). The release of the dye was measured over 24 h using a tear flow rate of 5 µL/min.

Results: Approximately 25% of the fluid that flowed over the eye model was lost due to evaporation, nonspecific absorption, and residual dead volume. Senofilcon A absorbed more dye (47.6 ± 2.7 µL) than etafilcon A (22.3 ± 2.0 µL). For etafilcon A, the release of the dye followed a burst-plateau profile in the vial but was sustained in the eye model. For senofilcon A, the release of the dye was sustained in both the vial and the eye model, though more dye was released in the vial ( < 0.05). Overall, the release of the dye from the contact lenses was higher in the vial compared with the eye model ( < 0.05).

Conclusion: The blink model developed in this study could be used to measure the release of topical ophthalmic drugs or comfort agents from contact lenses. Simulation of a blink mechanism, an artificial tear film, and nonspecific absorption in an eye model may provide better results than a simple, static vial incubation model.

Citing Articles

Current microfluidic platforms for reverse engineering of cornea.

Li Q, Wong H, Ip Y, Chu W, Li M, Saha C Mater Today Bio. 2023; 20:100634.

PMID: 37139464 PMC: 10149412. DOI: 10.1016/j.mtbio.2023.100634.


In vitro-in vivo correlation of drug release profiles from medicated contact lenses using an in vitro eye blink model.

Pereira-da-Mota A, Vivero-Lopez M, Garg P, Phan C, Concheiro A, Jones L Drug Deliv Transl Res. 2022; 13(4):1116-1127.

PMID: 36528710 PMC: 9981533. DOI: 10.1007/s13346-022-01276-6.


Suppression of Intracellular Reactive Oxygen Species in Human Corneal Epithelial Cells via the Combination of Quercetin Nanoparticles and Epigallocatechin Gallate and In Situ Thermosensitive Gel Formulation for Ocular Drug Delivery.

Chittasupho C, Junmahasathien T, Chalermmongkol J, Wongjirasakul R, Leesawat P, Okonogi S Pharmaceuticals (Basel). 2021; 14(7).

PMID: 34358106 PMC: 8308701. DOI: 10.3390/ph14070679.


3D Printing in Eye Care.

Larochelle R, Mann S, Ifantides C Ophthalmol Ther. 2021; 10(4):733-752.

PMID: 34327669 PMC: 8320416. DOI: 10.1007/s40123-021-00379-6.

References
1.
Bajgrowicz M, Phan C, Subbaraman L, Jones L . Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model. Invest Ophthalmol Vis Sci. 2015; 56(4):2234-42. DOI: 10.1167/iovs.15-16379. View

2.
Walther H, Lorentz H, Heynen M, Kay L, Jones L . Factors that influence in vitro cholesterol deposition on contact lenses. Optom Vis Sci. 2013; 90(10):1057-65. DOI: 10.1097/OPX.0000000000000022. View

3.
Qiao H, Phan C, Walther H, Subbaraman L, Jones L . Depth Profile Assessment of the Early Phase Deposition of Lysozyme on Soft Contact Lens Materials Using a Novel In Vitro Eye Model. Eye Contact Lens. 2017; 44 Suppl 2:S11-S18. DOI: 10.1097/ICL.0000000000000397. View

4.
Hui A . Contact lenses for ophthalmic drug delivery. Clin Exp Optom. 2017; 100(5):494-512. DOI: 10.1111/cxo.12592. View

5.
Lorentz H, Heynen M, Trieu D, Hagedorn S, Jones L . The impact of tear film components on in vitro lipid uptake. Optom Vis Sci. 2012; 89(6):856-67. DOI: 10.1097/OPX.0b013e318255ddc8. View