Overview
Journal Cureus
Date 2021 Mar 4
PMID 33659133
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiovascular implantable electronic device (CIED) has helped with advanced technological improvement in the cardiac field and has been a long-term alternative to medical management. There are different forms of CIEDs such as pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy. These devices are efficient in establishing near-normal hemodynamics and circulation that ultimately aid physicians to improve the quality of life for their patients. However, there are risk factors that can result in postoperative complications, including infection, lead and pulse generator complications, heart complications, medication-related complications, and psychosocial complications. To ensure optimal outcome of CIED placement, preprocedural measures need to be in place such as matching the right candidate and using appropriate devices. This review aims to highlight the surgical techniques for CIEDs, the associated postoperative complications, and long-term health effects.

Citing Articles

Fat Liquefaction and Lipo Particles in a CIED Pocket During Generator Change-Not an Infection: A Rare Case Report.

Guan A, He T, Huang X, Xia W, Shao Y Int Med Case Rep J. 2025; 18():53-58.

PMID: 39811102 PMC: 11730515. DOI: 10.2147/IMCRJ.S505053.


Biocompatible Electrical and Optical Interfaces for Implantable Sensors and Devices.

Wan Y, Wang C, Zhang B, Liu Y, Yang H, Liu F Sensors (Basel). 2024; 24(12).

PMID: 38931581 PMC: 11207811. DOI: 10.3390/s24123799.

References
1.
Osoro M, Lorson W, Hirsh J, Mahlow W . Use of an antimicrobial pouch/envelope in the treatment of Twiddler's syndrome. Pacing Clin Electrophysiol. 2017; 41(2):136-142. DOI: 10.1111/pace.13259. View

2.
Klein R, Raitt M, Wilkoff B, Beckman K, Coromilas J, Wyse D . Analysis of implantable cardioverter defibrillator therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial. J Cardiovasc Electrophysiol. 2003; 14(9):940-8. DOI: 10.1046/j.1540-8167.2003.01554.x. View

3.
Rohacek M, Baddour L . Cardiovascular implantable electronic device infections: associated risk factors and prevention. Swiss Med Wkly. 2015; 145:w14157. DOI: 10.4414/smw.2015.14157. View

4.
Hauser R, Hayes D, Almquist A, EPSTEIN A, Parsonnet V, Tyers G . Unexpected ICD pulse generator failure due to electronic circuit damage caused by electrical overstress. Pacing Clin Electrophysiol. 2001; 24(7):1046-54. DOI: 10.1046/j.1460-9592.2001.01046.x. View

5.
Wiggins N, Chong D, Houghtaling P, Hussein A, Saliba W, Sabik J . Incidence, indications, risk factors, and survival of patients undergoing cardiac implantable electronic device implantation after open heart surgery. Europace. 2016; 19(8):1335-1342. DOI: 10.1093/europace/euw234. View