» Articles » PMID: 33615085

Versatile Bipolar Temperature Controller for Custom Applications

Overview
Journal HardwareX
Date 2021 Feb 22
PMID 33615085
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Effective temperature control is crucial in many studies of isolated biological tissues, with preparations often requiring specialized holding chambers. In these situations, the design flexibility and optimizations offered by a custom made temperature controller may be preferable over a commercial model. We present a versatile controller for heating and cooling applications, providing simple step-by-step instructions to mathematically model your specific system and optimize controller parameters. The apparatus uses analog components and linear stages to simplify circuit comprehension and customization, achieving fast transitions with small static errors and overshoots over a wide range of temperatures without readjustment. A fully featured rackable enclosure is complemented by two temperature probes based on the LMT70A linear microchip sensor (for the control loop and for bath monitoring). BNC outputs provide scaled probe signals for continuous temperature data acquisition. The maximum achievable power output of the controller is -23.5 W/+22.0 W (-4.7 V/+4.4 V, ±5.0 A), sufficient to bring a well designed holder for standard 35 mm chambers from 23 °C up to 37 °C in ~1 min and down to 3 °C in ~4 min. Any biologist with some technical prowess should be able to follow our instructions from modeling to assembly and calibration.

Citing Articles

Recombinant protein delivery enables modulation of the phototransduction cascade in mouse retina.

Asteriti S, Marino V, Avesani A, Biasi A, Dal Cortivo G, Cangiano L Cell Mol Life Sci. 2023; 80(12):371.

PMID: 38001384 PMC: 10673981. DOI: 10.1007/s00018-023-05022-0.


An Ex Vivo Electroretinographic Apparatus for the mL-Scale Testing of Drugs to One Day and Beyond.

Cangiano L, Asteriti S Int J Mol Sci. 2023; 24(14).

PMID: 37511106 PMC: 10380068. DOI: 10.3390/ijms241411346.


A hybrid stochastic/deterministic model of single photon response and light adaptation in mouse rods.

Beelen C, Asteriti S, Cangiano L, Koch K, DellOrco D Comput Struct Biotechnol J. 2021; 19:3720-3734.

PMID: 34285774 PMC: 8258797. DOI: 10.1016/j.csbj.2021.06.033.

References
1.
Asteriti S, Grillner S, Cangiano L . A Cambrian origin for vertebrate rods. Elife. 2015; 4. PMC: 4502669. DOI: 10.7554/eLife.07166. View

2.
Correges P, BUGNARD E, Millerin C, Masiero A, Andrivet J, Bloc A . A simple, low-cost and fast Peltier thermoregulation set-up for electrophysiology. J Neurosci Methods. 1998; 83(2):177-84. DOI: 10.1016/s0165-0270(98)00079-x. View

3.
Cangiano L, Asteriti S, Cervetto L, Gargini C . The photovoltage of rods and cones in the dark-adapted mouse retina. J Physiol. 2012; 590(16):3841-55. PMC: 3476636. DOI: 10.1113/jphysiol.2011.226878. View

4.
Donner K, Hemila S, Koskelainen A . Temperature-dependence of rod photoresponses from the aspartate-treated retina of the frog (Rana temporaria). Acta Physiol Scand. 1988; 134(4):535-41. DOI: 10.1111/j.1748-1716.1998.tb08528.x. View

5.
Asteriti S, Gargini C, Cangiano L . Connexin 36 expression is required for electrical coupling between mouse rods and cones. Vis Neurosci. 2017; 34:E006. DOI: 10.1017/S0952523817000037. View