Safety and Feasibility of 2 h of Normothermic Machine Perfusion of Donor Kidneys in the Eurotransplant Senior Program
Overview
Authors
Affiliations
Background: The 5-year graft survival rate of donor kidneys transplanted in the Eurotransplant Senior Program (ESP) is only 47 per cent. Normothermic machine perfusion (NMP) may be a new preservation technique that improves graft outcome. This pilot study aimed to assess safety and feasibility of this technique within the ESP.
Methods: Recipients were eligible for inclusion if they received a donor kidney within the ESP. Donor kidneys underwent 2 h of oxygenated NMP with a red cell-based solution at 37°C, additional to standard-of-care preservation (non-oxygenated hypothermic machine perfusion). The primary outcome was the safety and feasibility of NMP. As a secondary outcome, graft outcome was investigated and compared with that in a historical group of patients in the ESP and the contralateral kidneys.
Results: Eleven patients were included in the NMP group; the function of eight kidneys could be compared with that of the contralateral kidney. Fifty-three patients in the ESP, transplanted consecutively between 2016 and 2018, were included as controls. No adverse events were noted, especially no arterial thrombosis or primary non-function of the transplants. After 120 min of oxygenated NMP, median flow increased from 117 (i.q.r. 80-126) to 215 (170-276) ml/min (P = 0.001). The incidence of immediate function was 64 per cent in the NMP group and 40 per cent in historical controls (P = 0.144). A significant difference in graft outcome was not observed.
Discussion: This pilot study showed NMP to be safe and feasible in kidneys transplanted in the ESP. A well powered study is warranted to confirm these results and investigate the potential advantages of NMP on graft outcome.
Fang Y, Ambagtsheer G, Xia L, Clahsen-van Groningen M, Minnee R, de Bruin R Heliyon. 2025; 11(2):e41610.
PMID: 39877618 PMC: 11773052. DOI: 10.1016/j.heliyon.2024.e41610.
de Boer E, Sokolova M, Jager N, Schjalm C, Weiss M, Liavag O Transpl Int. 2024; 37:13348.
PMID: 39606689 PMC: 11598510. DOI: 10.3389/ti.2024.13348.
Steinhauser C, Yakac A, Markgraf W, Kromnik S, Docke A, Talhofer P Int J Mol Sci. 2024; 25(19).
PMID: 39408610 PMC: 11476884. DOI: 10.3390/ijms251910280.
Montagud-Marrahi E, Luque Y, Ros R, Ajami T, Cuadrado-Payan E, Estrella H Front Bioeng Biotechnol. 2024; 11:1330043.
PMID: 38283171 PMC: 10811075. DOI: 10.3389/fbioe.2023.1330043.
48 h Normothermic Machine Perfusion With Urine Recirculation for Discarded Human Kidney Grafts.
Messner F, Soleiman A, Ofner D, Neuwirt H, Schneeberger S, Weissenbacher A Transpl Int. 2023; 36:11804.
PMID: 37901298 PMC: 10603233. DOI: 10.3389/ti.2023.11804.