» Articles » PMID: 33596036

Rapid Detection of SARS-CoV-2 Antigens Using High-Purity Semiconducting Single-Walled Carbon Nanotube-Based Field-Effect Transistors

Overview
Date 2021 Feb 17
PMID 33596036
Citations 61
Authors
Affiliations
Soon will be listed here.
Abstract

Early diagnosis of SARS-CoV-2 infection is critical for facilitating proper containment procedures, and a rapid, sensitive antigen assay is a critical step in curbing the pandemic. In this work, we report the use of a high-purity semiconducting (sc) single-walled carbon nanotube (SWCNT)-based field-effect transistor (FET) decorated with specific binding chemistry to assess the presence of SARS-CoV-2 antigens in clinical nasopharyngeal samples. Our SWCNT FET sensors, with functionalization of the anti-SARS-CoV-2 spike protein antibody (SAb) and anti-nucleocapsid protein antibody, detected the S antigen (SAg) and N antigen (NAg), reaching a limit of detection of 0.55 fg/mL for SAg and 0.016 fg/mL for NAg in calibration samples. SAb-functionalized FET sensors also exhibited good sensing performance in discriminating positive and negative clinical samples, indicating a proof of principle for use as a rapid COVID-19 antigen diagnostic tool with high analytical sensitivity and specificity at low cost.

Citing Articles

Recent advances in nanomaterials for the detection of mycobacterium tuberculosis (Review).

Zhu J, Wang H, Chen L Int J Mol Med. 2024; 55(3.

PMID: 39717951 PMC: 11722055. DOI: 10.3892/ijmm.2024.5477.


Electrochemical protein biosensors for disease marker detection: progress and opportunities.

Guo L, Zhao Y, Huang Q, Huang J, Tao Y, Chen J Microsyst Nanoeng. 2024; 10:65.

PMID: 38784375 PMC: 11111687. DOI: 10.1038/s41378-024-00700-w.


AlO/ZrO dual-dielectric Gr/CNT nanoribbon vertical tunnel FET based biosensor for genomic classification and S-protein detection in SARS-CoV-2.

Venkatesh M, Parthasarathy P Heliyon. 2024; 10(9):e30077.

PMID: 38707330 PMC: 11066398. DOI: 10.1016/j.heliyon.2024.e30077.


Detection of SARS-CoV-2 using dielectric modulated TFET-based biosensor.

Wangkheirakpam V, Bhowmick B, Pukhrambam P J Mater Sci Mater Electron. 2024; 33(13):10323-10334.

PMID: 38625001 PMC: 8926094. DOI: 10.1007/s10854-022-08020-3.


Sensing Characteristics of SARS-CoV-2 Spike Protein Using Aptamer-Functionalized Si-Based Electrolyte-Gated Field-Effect Transistor (EGT).

Shin S, Kim S, Choi W, Do J, Son J, Kim K Biosensors (Basel). 2024; 14(3).

PMID: 38534231 PMC: 10967824. DOI: 10.3390/bios14030124.