Probing for Stomach Using the Focused Impedance Method (FIM)

Overview
Specialty Biophysics
Date 2021 Feb 15
PMID 33584886
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

For probing deep organs of the body using electrical impedance, the conventional method is to use Electrical Impedance Tomography (EIT). However, this would be a sophisticated machine and will be very expensive when a full 3D EIT is developed in the future. Furthermore, for most low income countries such expensive devices may not deliver the benefits to a large number of people. Therefore, this paper suggests the use of simpler techniques like Tetrapolar Impedance Measurement (TPIM) or Focused Impedance Method (FIM) in probing deeper organs. Following a method suggested earlier by one of the authors, this paper studies the possibility of using TPIM and FIM for the stomach. Using a simplified model of the human trunk with an embedded stomach, a finite element simulation package, COMSOL, was used to obtain transfer impedance values and percentage contribution of the stomach region in the total impedance. For this work, judicious placement of electrodes through qualitative visualizations based on point sensitivity equations and equipotential concepts were made, which showed that reasonable contribution of the stomach region is possible through the use of TPIM and FIM. The contributions were a little over 20% which is of similar order of the cross-sectional area percentage of the stomach with respect to that of the trunk. For the case where the conductivity of the stomach region was assumed about 4 times higher, the contributions increased to about 38%. Through further studies this proposed methods may contribute greatly in the study of deeper organs of the body.

Citing Articles

Improving sensitivity in the deep regions of a volume conductor using electrical focused impedance methods.

Mobarak M, Rabbani K J Electr Bioimpedance. 2024; 15(1):107-115.

PMID: 39253094 PMC: 11381942. DOI: 10.2478/joeb-2024-0012.


Regional Pulmonary Ventilation Assessment Method and System Based on Impedance Sensing Information from the Pentapulmonary Lobes.

Zhang Y, Song C, He W, Zhang Q, Zhao P, Wang J Sensors (Basel). 2024; 24(10).

PMID: 38794056 PMC: 11124947. DOI: 10.3390/s24103202.

References
1.
Kushner R, Schoeller D . Estimation of total body water by bioelectrical impedance analysis. Am J Clin Nutr. 1986; 44(3):417-24. DOI: 10.1093/ajcn/44.3.417. View

2.
HENDERSON R, Webster J . An impedance camera for spatially specific measurements of the thorax. IEEE Trans Biomed Eng. 1978; 25(3):250-4. DOI: 10.1109/TBME.1978.326329. View

3.
Rabbani K, Kabir A . Studies on the effect of the third dimension on a two-dimensional electrical impedance tomography system. Clin Phys Physiol Meas. 1991; 12(4):393-402. DOI: 10.1088/0143-0815/12/4/009. View

4.
Lukaski H, Johnson P, Bolonchuk W, Lykken G . Assessment of fat-free mass using bioelectrical impedance measurements of the human body. Am J Clin Nutr. 1985; 41(4):810-7. DOI: 10.1093/ajcn/41.4.810. View

5.
Baker L . Principles of the impedance technique. IEEE Eng Med Biol Mag. 1989; 8(1):11-5. DOI: 10.1109/51.32398. View