» Articles » PMID: 33580325

Evaluation of Ion/electron Beam Induced Deposition for Electrical Connection Using a Modern Focused Ion Beam System

Overview
Journal Appl Microsc
Publisher Springer
Date 2021 Feb 13
PMID 33580325
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Focused ion beam method, which has excellent capabilities such as local deposition and selective etching, is widely used for micro-electromechanical system (MEMS)-based in situ transmission electron microscopy (TEM) sample fabrication. Among the MEMS chips in which one can apply various external stimuli, the electrical MEMS chips require connection between the TEM sample and the electrodes in MEMS chip, and a connected deposition material with low electrical resistance is required to apply the electrical signal. Therefore, in this study, we introduce an optimized condition by comparing the electrical resistance for C-, Pt-, and W- ion beam induced deposition (IBID) at 30 kV and electron beam induced deposition (EBID) at 1 and 5 kV. The W-IBID at 30 kV with the lowest electrical resistance of about 30 Ω shows better electrical properties than C- and Pt-IBID electrodes. The W-EBID at 1 kV has lower electrical resistance than that at 5 kV; thus, confirming its potential as an electrode. Therefore, for the materials that are susceptible to ion beam damage, it is recommended to fabricate electrical connections using W-EBID at 1 kV.

Citing Articles

Tutorial on In Situ and (Scanning) Transmission Electron Microscopy for Analysis of Nanoscale Structure-Property Relationships.

Smeaton M, Abellan P, Spurgeon S, Unocic R, Jungjohann K ACS Nano. 2024; 18(52):35091-35103.

PMID: 39690460 PMC: 11697340. DOI: 10.1021/acsnano.4c09256.


Use of PtC Nanotips for Low-Voltage Quantum Tunneling Applications.

Haub M, Guenther T, Bogner M, Zimmermann A Micromachines (Basel). 2022; 13(7).

PMID: 35888836 PMC: 9317598. DOI: 10.3390/mi13071019.

References
1.
Kato N . Reducing focused ion beam damage to transmission electron microscopy samples. J Electron Microsc (Tokyo). 2004; 53(5):451-8. DOI: 10.1093/jmicro/dfh080. View

2.
Hammad Fawey M, Chakravadhanula V, Reddy M, Rongeat C, Scherer T, Hahn H . In situ TEM studies of micron-sized all-solid-state fluoride ion batteries: Preparation, prospects, and challenges. Microsc Res Tech. 2016; 79(7):615-24. DOI: 10.1002/jemt.22675. View

3.
Mele L, Konings S, Dona P, Evertz F, Mitterbauer C, Faber P . A MEMS-based heating holder for the direct imaging of simultaneous in-situ heating and biasing experiments in scanning/transmission electron microscopes. Microsc Res Tech. 2016; 79(4):239-50. DOI: 10.1002/jemt.22623. View

4.
Vijayan S, Jinschek J, Kujawa S, Greiser J, Aindow M . Focused Ion Beam Preparation of Specimens for Micro-Electro-Mechanical System-based Transmission Electron Microscopy Heating Experiments. Microsc Microanal. 2017; 23(4):708-716. DOI: 10.1017/S1431927617000605. View

5.
Wilhite P, Uh H, Kanzaki N, Wang P, Vyas A, Maeda S . Electron-beam and ion-beam-induced deposited tungsten contacts for carbon nanofiber interconnects. Nanotechnology. 2014; 25(37):375702. DOI: 10.1088/0957-4484/25/37/375702. View