Anatomical Correlation Between Left Atrium Pulmonary Vein Ablation Targets of Atrial Fibrillation and Adjacent Bronchi and Pulmonary Arteries by MSCT

Overview
Publisher Biomed Central
Date 2021 Feb 11
PMID 33568060
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The ablation targets of atrial fibrillation (AF) are adjacent to bronchi and pulmonary arteries (PAs). We used computed tomography (CT) to evaluate the anatomical correlation between left atrium (LA)-pulmonary vein (PV) and adjacent structures.

Methods: Data were collected from 126 consecutive patients using coronary artery CT angiography. The LA roof was divided into three layers and nine points. The minimal spatial distances from the nine points and four PV orifices to the adjacent bronchi and PAs were measured. The distances from the PV orifices to the nearest contact points of the PVs, bronchi, and PAs were measured.

Results: The anterior points of the LA roof were farther to the bronchi than the middle or posterior points. The distances from the nine points to the PAs were shorter than those to the bronchi (5.19 ± 3.33 mm vs 8.62 ± 3.07 mm; P < .001). The bilateral superior PV orifices, especially the right superior PV orifices were closer to the PAs than the inferior PV orifices (left superior PV: 7.59 ± 4.14 mm; right superior PV: 4.43 ± 2.51 mm; left inferior PV: 24.74 ± 5.26 mm; right inferior PV: 22.33 ± 4.75 mm) (P < .001).

Conclusions: The right superior PV orifices were closer to the bronchi and PAs than other PV orifices. The ablation at the mid-posterior LA roof had a higher possibility to damage bronchi. CT is a feasible method to assess the anatomical adjacency in vivo, which might provide guidance for AF ablation.

References
1.
Li Y, Yang M, Li Y, Wang Q, Yu L, Sun J . Spatial relationship between left atrial roof or superior pulmonary veins and bronchi or pulmonary arteries by dual-source computed tomography: implication for preventing injury of bronchi and pulmonary arteries during atrial fibrillation ablation. Europace. 2011; 13(6):809-14. DOI: 10.1093/europace/eur034. View

2.
Bourier F, Duchateau J, Vlachos K, Lam A, Martin C, Takigawa M . High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics. J Cardiovasc Electrophysiol. 2018; 29(11):1570-1575. DOI: 10.1111/jce.13724. View

3.
Velghe D, Apers T, Devriendt S, Deblier I, Hendriks B, Nieuwendijk R . Atriobronchial Fistula Complicated by Septic Cerebral Air Emboli After Pulmonary Vein Ablation. Crit Care Med. 2017; 45(8):e867-e871. DOI: 10.1097/CCM.0000000000002438. View

4.
Aryana A, Bowers M, Hayatdavoudi S, Zhang Y, Afify A, dAvila A . Impact of Pulmonary Vein Cryoballoon Ablation on Bronchial Injury. J Cardiovasc Electrophysiol. 2016; 27(7):861-7. DOI: 10.1111/jce.12983. View

5.
Wu M, Wongcharoen W, Tsao H, Tai C, Chang S, Lin Y . Close relationship between the bronchi and pulmonary veins: implications for the prevention of atriobronchial fistula after atrial fibrillation ablation. J Cardiovasc Electrophysiol. 2007; 18(10):1056-9. DOI: 10.1111/j.1540-8167.2007.00915.x. View