» Articles » PMID: 33547550

Detection of Chlorantraniliprole Residues in Tomato Using Field-deployable MIP Photonic Sensors

Overview
Journal Mikrochim Acta
Specialties Biotechnology
Chemistry
Date 2021 Feb 6
PMID 33547550
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

A photonic sensor based on inversed opal molecular imprinted polymer (MIP) film to detect the presence of chlorantraniliprole (CHL) residue in tomatoes was developed. Acrylic acid was polymerized in the presence of CHL inside the structure of a colloidal crystal, followed by etching of the colloids and CHL elution. Colloidal crystals and MIP films were characterized by scanning electron microscopy and FT-IR, confirming the inner structure and chemical structure of the material. MIP films supported on polymethylmethacrylate (PMMA) slides were incubated in aqueous solutions of the pesticide and in blended tomato samples. The MIP sensor displayed shifts of the peak wavelength of the reflection spectra in the visible range when incubated in CHL concentrations between 0.5 and 10 μg L, while almost no peak displacement was observed for non-imprinted (NIP) films. Whole tomatoes were blended into a liquid and spiked with CHL; the sensor was able to detect CHL residues down to 0.5 μg kg, significantly below the tolerance level established by the US Environmental Protection Agency of 1.4 mg kg. Stable values were reached after about 30-min incubation in test samples. Control samples (unspiked processed tomatoes) produced peak shifts both in MIP and NIP films; however, this matrix effect did not affect the detection of CHL in the spiked samples. These promising results support the application of photonic MIP sensors as an economical and field-deployable screening tool for the detection of CHL in crops.

Citing Articles

A Robust Method for the Elaboration of SiO-Based Colloidal Crystals as a Template for Inverse Opal Structures.

Fookes F, Polo Parada L, Fidalgo M Sensors (Basel). 2023; 23(3).

PMID: 36772472 PMC: 9920682. DOI: 10.3390/s23031433.

References
1.
Ashley J, Shahbazi M, Kant K, Chidambara V, Wolff A, Bang D . Molecularly imprinted polymers for sample preparation and biosensing in food analysis: Progress and perspectives. Biosens Bioelectron. 2017; 91:606-615. DOI: 10.1016/j.bios.2017.01.018. View

2.
Fathi F, Rashidi M, Pakchin P, Ahmadi-Kandjani S, Nikniazi A . Photonic crystal based biosensors: Emerging inverse opals for biomarker detection. Talanta. 2020; 221:121615. PMC: 7466948. DOI: 10.1016/j.talanta.2020.121615. View

3.
Lin Z, Li L, Fu G, Lai Z, Peng A, Huang Z . Molecularly imprinted polymer-based photonic crystal sensor array for the discrimination of sulfonamides. Anal Chim Acta. 2020; 1101:32-40. DOI: 10.1016/j.aca.2019.12.032. View

4.
Wang X, Mu Z, Liu R, Pu Y, Yin L . Molecular imprinted photonic crystal hydrogels for the rapid and label-free detection of imidacloprid. Food Chem. 2013; 141(4):3947-53. DOI: 10.1016/j.foodchem.2013.06.024. View

5.
Farooq S, Nie J, Cheng Y, Yan Z, Bacha S, Zhang J . Synthesis of core-shell magnetic molecularly imprinted polymer for the selective determination of imidacloprid in apple samples. J Sep Sci. 2019; 42(14):2455-2465. DOI: 10.1002/jssc.201900221. View