» Articles » PMID: 33546654

A Novel Posterior Multiple Screws Distraction Reducer System Versus Anterior Release, Posterior Internal Distraction, and Subsequent Spinal Fusion for Severe Scoliosis

Overview
Publisher Biomed Central
Specialties Orthopedics
Physiology
Date 2021 Feb 6
PMID 33546654
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: We previously reported anterior release, posterior internal distraction, and subsequent spinal fusion (ARPIDF) for the correction of severe scoliosis with a satisfactory correction rate. However, surgical procedures were completed in 2-3 stages. Here we compare Cobb angle of ≥90° in scoliosis correction between a novel posterior multiple screws distraction reducer (MSDR) system and ARPIDF.

Methods: Thirty-six patients with severe scoliosis treated by MSDR or ARPIDF (n = 18 in both groups). We retrospectively analyzed and compared outcome measures between the two groups over a minimum follow-up duration of 2 years. The following variables were compared between the two groups: age at surgery, sex, etiology, flexibility of the main thoracic curve, number of fused segments and screws, operation time, estimated blood loss, hospitalization time, follow-up duration, various radiological parameters, complication rate, and Scoliosis Research Society-30 score.

Results: There were no significant between-group differences with respect to age, sex, etiology, flexibility of the main thoracic curve, number of fused segments and screws, and follow-up duration. Further, there was no significant difference in terms of preoperative, postoperative, and final follow-up findings of the radiographic data. However, the ARPIDF group had longer operation and hospitalization times and greater blood loss. In the ARPIDF group, 4 patient developed complications (infection, intraoperative neuromonitoring changes, transient dyspnea); none of these events occurred in the MSDR group.

Conclusion: The use of MSDR helped achieve greater scoliosis correction with a shorter operation time, lower blood loss, and lower complication rate than the use of ARPIDF. MSDR facilitates safer and easier correction of severe scoliosis without increasing surgical risk.

Citing Articles

A Novel Multiple Screw Distraction Reducer System in the Treatment of Scoliosis with a Severe Rib Hump.

Deng Z, Wang L, Liu L, Wang L, Yang X, Song Y Orthop Surg. 2023; 16(1):47-56.

PMID: 38010853 PMC: 10782260. DOI: 10.1111/os.13943.

References
1.
Zhang H, Sucato D . A Novel Posterior Rod-Link-Reducer System Provides Safer, Easier, and Better Correction of Severe Scoliosis. Spine Deform. 2019; 7(3):445-453. DOI: 10.1016/j.jspd.2018.09.001. View

2.
Suk S, Chung E, Lee S, Lee J, Kim S, Kim J . Posterior vertebral column resection in fixed lumbosacral deformity. Spine (Phila Pa 1976). 2005; 30(23):E703-10. DOI: 10.1097/01.brs.0000188190.90034.be. View

3.
Lenke L, Sides B, Koester L, Hensley M, Blanke K . Vertebral column resection for the treatment of severe spinal deformity. Clin Orthop Relat Res. 2009; 468(3):687-99. PMC: 2816784. DOI: 10.1007/s11999-009-1037-x. View

4.
Bullmann V, Halm H, Schulte T, Lerner T, Weber T, Liljenqvist U . Combined anterior and posterior instrumentation in severe and rigid idiopathic scoliosis. Eur Spine J. 2006; 15(4):440-8. PMC: 3489309. DOI: 10.1007/s00586-005-1016-1. View

5.
Shen J, Qiu G, Wang Y, Zhang Z, Zhao Y . Comparison of 1-stage versus 2-stage anterior and posterior spinal fusion for severe and rigid idiopathic scoliosis--a randomized prospective study. Spine (Phila Pa 1976). 2006; 31(22):2525-8. DOI: 10.1097/01.brs.0000240704.42264.c4. View