» Articles » PMID: 33523184

High-power Short Duration Vs. Conventional Radiofrequency Ablation of Atrial Fibrillation: a Systematic Review and Meta-analysis

Overview
Journal Europace
Date 2021 Feb 1
PMID 33523184
Citations 40
Authors
Affiliations
Soon will be listed here.
Abstract

Aims: We sought to compare the effectiveness and safety of high-power short-duration (HPSD) radiofrequency ablation (RFA) with conventional RFA in patients with atrial fibrillation (AF).

Methods And Results: MEDLINE, Cochrane, and ClinicalTrials.gov databases were searched until 15 May 2020 for relevant studies comparing HPSD vs. conventional RFA in patients undergoing initial catheter ablation for AF. A total of 15 studies involving 3718 adult patients were included in our meta-analysis (2357 in HPSD RFA and 1361 in conventional RFA). Freedom from atrial arrhythmia was higher in HPSD RFA when compared with conventional RFA [odds ratio (OR) 1.44, 95% confidence interval (CI) 1.10-1.90; P = 0.009]. Acute PV reconnection was lower (OR 0.56, P = 0.005) and first-pass isolation was higher (OR 3.58, P < 0.001) with HPSD RFA. There was no difference in total complications between the two groups (P = 0.19). Total procedure duration [mean difference (MD) -37.35 min, P < 0.001], fluoroscopy duration (MD -5.23 min, P = 0.001), and RF ablation time (MD -16.26 min, P < 0.001) were all significantly lower in HPSD RFA. High-power short-duration RFA also demonstrated higher freedom from atrial arrhythmia in the subgroup analysis of patients with paroxysmal AF (OR 1.80, 95% CI 1.29-2.50; P < 0.001), studies with ≥50 W protocol in the HPSD RFA group (OR 1.53, 95% CI 1.08-2.18; P = 0.02] and studies with contact force sensing catheter use (OR 1.65, 95% CI 1.21-2.25; P = 0.002).

Conclusion: High-power short-duration RFA was associated with better procedural effectiveness when compared with conventional RFA with comparable safety and shorter procedural duration.

Citing Articles

Esophageal cooling vs luminal esophageal temperature monitoring in high-power short-duration ablation of paroxysmal atrial fibrillation.

Kayani W, Schricker A, Nerlekar R, Earnest B, Hongo R, Hao S J Interv Card Electrophysiol. 2025; .

PMID: 39953307 DOI: 10.1007/s10840-025-02016-9.


Contemporary Trends in Pulsed Field Ablation for Cardiac Arrhythmias.

Yavin H, Prasad M, Gordon J, Aksu T, Huang H J Cardiovasc Dev Dis. 2025; 12(1).

PMID: 39852288 PMC: 11766314. DOI: 10.3390/jcdd12010010.


High-power short-duration setting prevents changes of periprocedural thrombotic markers and the onset of silent stroke in patients with atrial fibrillation.

Kamioka M, Watanabe T, Watanabe H, Okuyama T, Yokota A, Komori T Heart Rhythm O2. 2025; 5(12):917-924.

PMID: 39803620 PMC: 11721730. DOI: 10.1016/j.hroo.2024.09.019.


2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation.

Tzeis S, Gerstenfeld E, Kalman J, Saad E, Sepehri Shamloo A, Andrade J J Arrhythm. 2024; 40(6):1217-1354.

PMID: 39669937 PMC: 11632303. DOI: 10.1002/joa3.13082.


Caudal vena cava isolation using ablation index-guided radiofrequency catheter ablation (CARTO™ 3) to treat sustained atrial tachycardia in horses.

Buschmann E, Van Steenkiste G, Vernemmen I, Demeyere M, Schauvliege S, Decloedt A J Vet Intern Med. 2024; 39(1):e17251.

PMID: 39614765 PMC: 11638121. DOI: 10.1111/jvim.17251.