Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.

Citing Articles

Biomechanical Analysis of Truncated Cone Implants for Maxillary Sinus Lift: An In Vitro Study on Polyurethane Laminas.

Comuzzi L, Romasco T, Mourao C, Marchioli G, Piattelli A, Di Pietro N Bioengineering (Basel). 2025; 12(1).

PMID: 39851327 PMC: 11761941. DOI: 10.3390/bioengineering12010053.


Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study.

Fakhr M, Alansary H, Hassanien E BMC Oral Health. 2024; 24(1):1073.

PMID: 39261788 PMC: 11391652. DOI: 10.1186/s12903-024-04810-9.


Conometric Connection for Implant-Supported Crowns: A Prospective Clinical Cohort Study.

Lupi S, De Martis D, Todaro C, Isola G, Beretta M, Rodriguez Y Baena R J Clin Med. 2023; 12(24).

PMID: 38137716 PMC: 10743547. DOI: 10.3390/jcm12247647.

References
1.
Canullo L, Penarrocha M, Monje A, Catena A, Wang H, Penarrocha D . Association Between Clinical and Microbiologic Cluster Profiles and Peri-implantitis. Int J Oral Maxillofac Implants. 2017; 32(5):1054-1064. DOI: 10.11607/jomi.6043. View

2.
Hong M, Min B, Lee D, Kwon T . Marginal fit of metal-ceramic crowns fabricated by using a casting and two selective laser melting processes before and after ceramic firing. J Prosthet Dent. 2019; 122(5):475-481. DOI: 10.1016/j.prosdent.2019.03.002. View

3.
Dibart S, Warbington M, Su M, Skobe Z . In vitro evaluation of the implant-abutment bacterial seal: the locking taper system. Int J Oral Maxillofac Implants. 2005; 20(5):732-7. View

4.
Zipprich H, Miatke S, Hmaidouch R, Lauer H . A New Experimental Design for Bacterial Microleakage Investigation at the Implant-Abutment Interface: An In Vitro Study. Int J Oral Maxillofac Implants. 2016; 31(1):37-44. DOI: 10.11607/jomi.3713. View

5.
Ahrberg D, Lauer H, Ahrberg M, Weigl P . Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial. Clin Oral Investig. 2015; 20(2):291-300. DOI: 10.1007/s00784-015-1504-6. View