» Articles » PMID: 33472509

Microfluidics for the Rapid Detection of Escherichia Coli O157:H7 Using Antibody-coated Microspheres

Overview
Journal Bioengineered
Date 2021 Jan 21
PMID 33472509
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

This study developed a novel method for the rapid detection of () O157:H7 on a microfluidic platform. First, the concentration of bacteria in a sample was determined with the adenosine triphosphate (ATP) method. Then, the specific detection of was achieved in a microfluidic chip by the immune-microsphere technique. The influences of the culture time, flow rate and capture time on the detection of the target bacteria were investigated systematically. Generally, with increasing capture time, more bacteria could be captured by the microspheres, which had a positive effect on bacterial detection. Furthermore, the sensitivity and specificity of the method were also tested. The results showed that this method could specifically detect with a sensitivity as high as 49.1 cfu/μL; the consumption of bacteria was 1 μL, and the reagent was at the microliter level. The testing time can be controlled within one and a half hours, and the cost of testing was approximately RMB 10. The method described in this article is simple and accurate and has great application value in bacterial detection for medical diagnostics.

Citing Articles

Polymeric and Paper-Based Lab-on-a-Chip Devices in Food Safety: A Review.

Mitrogiannopoulou A, Tselepi V, Ellinas K Micromachines (Basel). 2023; 14(5).

PMID: 37241610 PMC: 10223399. DOI: 10.3390/mi14050986.


Proof of Concept for the Detection with Custom Printed Electrodes of Enterobactin as a Marker of .

Canciu A, Cernat A, Tertis M, Botarca S, Bordea M, Wang J Int J Mol Sci. 2022; 23(17).

PMID: 36077283 PMC: 9456371. DOI: 10.3390/ijms23179884.


A strategy design based on antibiotic‑resistance and plasmid replicons genes of clinical Escherichia coli strains.

Liu J, Lin X, Soteyome T, Ye Y, Chen D, Yang L Bioengineered. 2022; 13(3):7500-7514.

PMID: 35259054 PMC: 9208507. DOI: 10.1080/21655979.2022.2047543.

References
1.
Wu Q, Zhang Y, Yang Q, Yuan N, Zhang W . Review of Electrochemical DNA Biosensors for Detecting Food Borne Pathogens. Sensors (Basel). 2019; 19(22). PMC: 6891683. DOI: 10.3390/s19224916. View

2.
Kubo I, Kajiya M, Aramaki N, Furutani S . Detection of Salmonella Enterica in Egg Yolk by PCR on a Microfluidic Disc Device Using Immunomagnetic Beads. Sensors (Basel). 2020; 20(4). PMC: 7070913. DOI: 10.3390/s20041060. View

3.
Gao H, Yan C, Wu W, Li J . Application of Microfluidic Chip Technology in Food Safety Sensing. Sensors (Basel). 2020; 20(6). PMC: 7146374. DOI: 10.3390/s20061792. View

4.
Kasap E, Dogan U, Cogun F, Yildirim E, Boyaci I, Cetin D . Fast fluorometric enumeration of E. coli using passive chip. J Microbiol Methods. 2019; 164:105680. DOI: 10.1016/j.mimet.2019.105680. View

5.
Li N, Lu Y, Cheng J, Xu Y . A self-contained and fully integrated fluidic cassette system for multiplex nucleic acid detection of bacteriuria. Lab Chip. 2019; 20(2):384-393. DOI: 10.1039/c9lc00994a. View