Abstract

Glucose belongs among the most important substances in both physiology and industry. Current food and biotechnology praxis emphasizes its on-line continuous monitoring and regulation. These provoke increasing demand for systems, which enable fast detection and regulation of deviations from desired glucose concentration. We demonstrated control of glucose concentration by feedback regulation equipped with in situ optical fiber glucose sensor. The sensitive layer of the sensor comprises oxygen-dependent ruthenium complex and preimmobilized glucose oxidase both entrapped in organic-inorganic polymer ORMOCER. The sensor was placed in the laboratory bioreactor (volume 5 L) to demonstrate both regulations: the control of low levels of glucose concentrations (0.4 and 0.1 mM) and maintenance of the glucose concentration (between 2 and 3.5 mM) during stationary phase of cultivation of . Response times did not exceed 6 min (average 4 min) with average deviation of 4%. Due to these regulation characteristics together with durable and long-lasting (≥2 month) sensitive layer, this feedback regulation system might find applications in various biotechnological processes such as production of low glucose content beverages.

Citing Articles

Microsensor in Microbioreactors: Full Bioprocess Characterization in a Novel Capillary-Wave Microbioreactor.

Viebrock K, Rabl D, Meinen S, Wunder P, Meyer J, Frey L Biosensors (Basel). 2022; 12(7).

PMID: 35884315 PMC: 9312480. DOI: 10.3390/bios12070512.


Relationship between delayed luminescence emission and mitochondrial status in Saccharomyces cerevisiae.

Tian M, Li Q, Liu Y, Zheng P, Li D, Zhao Y Sci Rep. 2022; 12(1):394.

PMID: 35013471 PMC: 8748773. DOI: 10.1038/s41598-021-04290-9.

References
1.
Omer A, Shaker G, Safavi-Naeini S, Kokabi H, Alquie G, Deshours F . Low-cost portable microwave sensor for non-invasive monitoring of blood glucose level: novel design utilizing a four-cell CSRR hexagonal configuration. Sci Rep. 2020; 10(1):15200. PMC: 7494924. DOI: 10.1038/s41598-020-72114-3. View

2.
CLARK Jr L, Lyons C . Electrode systems for continuous monitoring in cardiovascular surgery. Ann N Y Acad Sci. 1962; 102:29-45. DOI: 10.1111/j.1749-6632.1962.tb13623.x. View

3.
Mehrotra P, Chatterjee B, Sen S . EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing. Sensors (Basel). 2019; 19(5). PMC: 6427747. DOI: 10.3390/s19051013. View

4.
Otten J, Tenhaef N, Jansen R, Dobber J, Jungbluth L, Noack S . A FRET-based biosensor for the quantification of glucose in culture supernatants of mL scale microbial cultivations. Microb Cell Fact. 2019; 18(1):143. PMC: 6704555. DOI: 10.1186/s12934-019-1193-y. View

5.
Clarke S, Foster J . A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. Br J Biomed Sci. 2012; 69(2):83-93. View