Measurement Properties of Handheld Dynamometry for Assessment of Shoulder Muscle Strength: A Systematic Review

Overview
Specialty Orthopedics
Date 2021 Jan 19
PMID 33463791
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Like any assessment tool, handheld dynamometry (HHD) must be valid and reliable in order to be meaningful in clinical practice and research. To summarize the evidence of measurement properties of HHD for the assessment of shoulder muscle strength. Cochrane Central Register of Controlled Trials (CENTRAL), PubMed, EMBASE, and PEDro were searched up to February 2020. Inclusion criteria were studies (a) evaluating HHD used on the glenohumeral joint, (b) evaluating measurement properties, and (c) included individuals ≥ 18 years old with or without shoulder symptoms. Exclusion criteria were studies (a) including patients with neurologic, neuromuscular, systemic diseases, or critical illness or bed-side patients and (b) that did not report the results separately for each movement. In total, 28 studies with 963 participants were included. The reliability results showed that 98% of the intraclass correlation coefficient (ICC) values were ≥0.70. The measurement error showed that the minimal detectable change in percent varied from 0% to 51.0%. The quality of evidence was high or moderate for the majority of movements and type of reliability examined. Based on the evidence of low or very low quality of evidence, the convergent validity and discriminative validity of HHD were either sufficient, indeterminate, or insufficient. The reliability of HHD was overall sufficient, and HHD can be used to distinguish between individuals on the group level. The measurement error was not sufficient, and evaluation of treatment effect on the individual level should be interpreted with caution.

Citing Articles

Design and validation of an alignment free adaptive joint torque measurement system.

Li L, Chen J, Sun S, Peng W Biomed Eng Online. 2025; 24(1):25.

PMID: 39994741 PMC: 11852568. DOI: 10.1186/s12938-025-01356-x.


Muscle strength measurements reflecting the extent of complete subscapularis tears: reliability in patients with rotator cuff tears.

Sahara W, Takagi K, Tada S, Yamada D, Kiya H, Hanai H JSES Int. 2025; 9(1):109-115.

PMID: 39898229 PMC: 11784269. DOI: 10.1016/j.jseint.2024.08.201.


Pole Dancing-Specific Muscle Strength: Development and Reliability of a Novel Assessment Protocol.

Ignatoglou D, Paliouras A, Paraskevopoulos E, Strimpakos N, Bilika P, Papandreou M Methods Protoc. 2024; 7(3).

PMID: 38804338 PMC: 11163365. DOI: 10.3390/mps7030044.


Reliability and Validity of the ActivForce Digital Dynamometer in Assessing Shoulder Muscle Force across Different User Experience Levels.

Karagiannopoulos C, Griech S, Leggin B Int J Sports Phys Ther. 2022; 17(4):669-676.

PMID: 35693865 PMC: 9159718. DOI: 10.26603/001c.35577.