» Articles » PMID: 33393992

Giant Magnetoresistive Nanosensor Analysis of Circulating Tumor DNA Epidermal Growth Factor Receptor Mutations for Diagnosis and Therapy Response Monitoring

Abstract

Background: Liquid biopsy circulating tumor DNA (ctDNA) mutational analysis holds great promises for precision medicine targeted therapy and more effective cancer management. However, its wide adoption is hampered by high cost and long turnaround time of sequencing assays, or by inadequate analytical sensitivity of existing portable nucleic acid tests to mutant allelic fraction in ctDNA.

Methods: We developed a ctDNA Epidermal Growth Factor Receptor (EGFR) mutational assay using giant magnetoresistive (GMR) nanosensors. This assay was validated in 36 plasma samples of non-small cell lung cancer patients with known EGFR mutations. We assessed therapy response through follow-up blood draws, determined concordance between the GMR assay and radiographic response, and ascertained progression-free survival of patients.

Results: The GMR assay achieved analytical sensitivities of 0.01% mutant allelic fraction. In clinical samples, the assay had 87.5% sensitivity (95% CI = 64.0-97.8%) for Exon19 deletion and 90% sensitivity (95% CI = 69.9-98.2%) for L858R mutation with 100% specificity; our assay detected T790M resistance with 96.3% specificity (95% CI = 81.7-99.8%) with 100% sensitivity. After 2 weeks of therapy, 10 patients showed disappearance of ctDNA by GMR (predicted responders), whereas 3 patients did not (predicted nonresponders). These predictions were 100% concordant with radiographic response. Kaplan-Meier analysis showed responders had significantly (P < 0.0001) longer PFS compared to nonresponders (N/A vs. 12 weeks, respectively).

Conclusions: The GMR assay has high diagnostic sensitivity and specificity and is well suited for detecting EGFR mutations at diagnosis and noninvasively monitoring treatment response at the point-of-care.

Citing Articles

Detecting N-Phenyl-2-Naphthylamine, L-Arabinose, D-Mannose, L-Phenylalanine, L-Methionine, and D-Trehalose via Photocurrent Measurement.

Li F, Yang R, Xu J, Xu G, Wu Y Gels. 2024; 10(12).

PMID: 39727566 PMC: 11675501. DOI: 10.3390/gels10120808.


Optical nanomaterial-based detection of biomarkers in liquid biopsy.

Kim Y, Rho W, Park S, Jun B J Hematol Oncol. 2024; 17(1):10.

PMID: 38486294 PMC: 10938695. DOI: 10.1186/s13045-024-01531-y.


High throughput isolation of RNA from single-cells within an intact tissue for spatial and temporal sequencing a reality.

Stanley J, Lohith A, Debiaso L, Wang K, Ton M, Cui W PLoS One. 2023; 18(8):e0289279.

PMID: 37527243 PMC: 10393160. DOI: 10.1371/journal.pone.0289279.


Longitudinal analysis of anti-SARS-CoV-2 neutralizing antibody (NAb) titers in vaccinees using a novel giant magnetoresistive (GMR) assay.

Ng E, Choi C, Wang S Sens Actuators B Chem. 2023; 387:133773.

PMID: 37056483 PMC: 10072976. DOI: 10.1016/j.snb.2023.133773.


Giant Magnetoresistance Biosensors for Food Safety Applications.

Liang S, Sutham P, Wu K, Mallikarjunan K, Wang J Sensors (Basel). 2022; 22(15).

PMID: 35957220 PMC: 9371012. DOI: 10.3390/s22155663.