Preliminary Experience with 088 Large Bore Intracranial Catheters During Stroke Thrombectomy

Overview
Publisher Sage Publications
Specialty Neurology
Date 2020 Dec 23
PMID 33353466
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Purpose: Thromboaspiration technology continues to evolve at an accelerated pace with increasing availability of larger and more navigable devices. Herein, we provide our initial experience with the intracranial navigation of a large-bore (.088" inner diameter) catheters during mechanical thrombectomy (MT).

Methods: Retrospective review of consecutive large vessel occlusion stroke patients in whom a TracStar™ or Zoom 88™ (Imperative Care, Campbell, CA) large-bore catheters were utilized in MT. The primary outcome was successful reperfusion (eTICI2b-3) at the end of the procedure. Safety measures included procedural complications and rates of symptomatic intracranial hemorrhage.

Results: Five patients (age,∼50-85 years; baseline NIHSS,17-23) were treated. The .088" catheters were used as the primary tool for contact aspiration in two patients (distal basilar artery and proximal MCA occlusions) with complete thrombus ingestion (eTICI3) during the first pass. In two patients, the .088" catheter was used for flow control where it was placed in the distal M1-segment of a patient with M2 occlusion treated with a combination of stent-retriever and .070" aspiration catheter and in the proximal M1 in a patient with distal M1 occlusion treated with .071" aspiration catheter resulting in eTICI3 reperfusion in both cases. In the fifth patient, the .088" catheter was navigated into the cavernous ICA to support .071" aspiration catheter treatment of an M2 occlusion resulting in eTCI2b67 reperfusion. Procedural duration ranged between 14 and 33 minutes. There were no adverse events.

Conclusion: Intracranial navigation of .088" large-bore catheters in MT appears technically feasible and safe. Larger prospective studies are warranted.

Citing Articles

Iatrogenic intracranial venous hypertension treated with intracranial venous stenting: illustrative case.

Snyder M, Heilman C, Malek A J Neurosurg Case Lessons. 2025; 9(10).

PMID: 40063991 PMC: 11894280. DOI: 10.3171/CASE24781.


A direct aspiration first-pass technique (ADAPT) for acute ischemic stroke thrombectomy: Indications, technique, and emerging devices.

Frauenfelder G, Diana F, Saponiero R, Romano D Neuroradiol J. 2024; :19714009241303063.

PMID: 39562014 PMC: 11577322. DOI: 10.1177/19714009241303063.


Thrombectomy using Zoom Reperfusion System in pediatric acute ischemic strokes: Case series and literature review.

Singh R, Verma U, Shakir H, Jen S Neuroradiol J. 2024; :19714009241247468.

PMID: 38695294 PMC: 11571359. DOI: 10.1177/19714009241247468.


Optimizing catheter centering enhances mechanical thrombectomy success: Performance difference in cases using novel macrowires versus traditional microwires.

Hassan A, Tekle W, Saei H Interv Neuroradiol. 2024; :15910199241249212.

PMID: 38676326 PMC: 11569756. DOI: 10.1177/15910199241249212.


Feasibility of super-bore 0.088″ mechanical thrombectomy in M1 vessels smaller than 8 French: Experience in 20 consecutive cases.

Campos J, Meyer B, Khan M, Laghari F, Zarrin D, de Beaufort J Interv Neuroradiol. 2024; :15910199241229198.

PMID: 38418397 PMC: 11573702. DOI: 10.1177/15910199241229198.


References
1.
Delgado Almandoz J, Kayan Y, Wallace A, Tarrel R, Fease J, Scholz J . Larger ACE 68 aspiration catheter increases first-pass efficacy of ADAPT technique. J Neurointerv Surg. 2018; 11(2):141-146. DOI: 10.1136/neurintsurg-2018-013957. View

2.
Froehler M . Comparison of Vacuum Pressures and Forces Generated by Different Catheters and Pumps for Aspiration Thrombectomy in Acute Ischemic Stroke. Interv Neurol. 2017; 6(3-4):199-206. PMC: 5662950. DOI: 10.1159/000475478. View

3.
Pandey A, Ringer A, Rai A, Kan P, Jabbour P, Siddiqui A . Minimizing SARS-CoV-2 exposure when performing surgical interventions during the COVID-19 pandemic. J Neurointerv Surg. 2020; 12(7):643-647. DOI: 10.1136/neurintsurg-2020-016161. View

4.
Fitzgerald S, Ryan D, Thornton J, Nogueira R . Preclinical evaluation of Millipede 088 intracranial aspiration catheter in cadaver and in vitro thrombectomy models. J Neurointerv Surg. 2020; 13(5):447-452. PMC: 8053321. DOI: 10.1136/neurintsurg-2020-016218. View

5.
Smoker W, Price M, Keyes W, Corbett J, Gentry L . High-resolution computed tomography of the basilar artery: 1. Normal size and position. AJNR Am J Neuroradiol. 1986; 7(1):55-60. PMC: 8334772. View