» Articles » PMID: 33339530

Inertial Sensor-based Gait Parameters Reflect Patient-reported Fatigue in Multiple Sclerosis

Overview
Publisher Biomed Central
Date 2020 Dec 19
PMID 33339530
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Multiple sclerosis (MS) is a disabling disease affecting the central nervous system and consequently the whole body's functional systems resulting in different gait disorders. Fatigue is the most common symptom in MS with a prevalence of 80%. Previous research studied the relation between fatigue and gait impairment using stationary gait analysis systems and short gait tests (e.g. timed 25 ft walk). However, wearable inertial sensors providing gait data from longer and continuous gait bouts have not been used to assess the relation between fatigue and gait parameters in MS. Therefore, the aim of this study was to evaluate the association between fatigue and spatio-temporal gait parameters extracted from wearable foot-worn sensors and to predict the degree of fatigue.

Methods: Forty-nine patients with MS (32 women; 17 men; aged 41.6 years, EDSS 1.0-6.5) were included where each participant was equipped with a small Inertial Measurement Unit (IMU) on each foot. Spatio-temporal gait parameters were obtained from the 6-min walking test, and the Borg scale of perceived exertion was used to represent fatigue. Gait parameters were normalized by taking the difference of averaged gait parameters between the beginning and end of the test to eliminate inter-individual differences. Afterwards, normalized parameters were transformed to principle components that were used as input to a Random Forest regression model to formulate the relationship between gait parameters and fatigue.

Results: Six principal components were used as input to our model explaining more than 90% of variance within our dataset. Random Forest regression was used to predict fatigue. The model was validated using 10-fold cross validation and the mean absolute error was 1.38 points. Principal components consisting mainly of stride time, maximum toe clearance, heel strike angle, and stride length had large contributions (67%) to the predictions made by the Random Forest.

Conclusions: The level of fatigue can be predicted based on spatio-temporal gait parameters obtained from an IMU based system. The results can help therapists to monitor fatigue before and after treatment and in rehabilitation programs to evaluate their efficacy. Furthermore, this can be used in home monitoring scenarios where therapists can monitor fatigue using IMUs reducing time and effort of patients and therapists.

Citing Articles

Smartphone-based gait analysis in the assessment of fatigue and fatigability in people with multiple sclerosis: a supervised cohort study.

Schonherr C, Ziegler J, Zentek T, Rashid A, Strauss S, Tallner A J Neurol. 2025; 272(3):217.

PMID: 39985679 PMC: 11846754. DOI: 10.1007/s00415-025-12906-7.


The Use of Artificial Intelligence and Wearable Inertial Measurement Units in Medicine: Systematic Review.

Smits Serena R, Hinterwimmer F, Burgkart R, von Eisenhart-Rothe R, Rueckert D JMIR Mhealth Uhealth. 2025; 13:e60521.

PMID: 39880389 PMC: 11822330. DOI: 10.2196/60521.


Inertial measurement units to evaluate the efficacity of Equino Varus Foot surgery in post stroke hemiparetic patients: a feasibility study.

De LEscalopier N, Voisard C, Jung S, Michaud M, Moreau A, Vayatis N J Neuroeng Rehabil. 2024; 21(1):182.

PMID: 39407309 PMC: 11481626. DOI: 10.1186/s12984-024-01469-9.


Ability of Nicotinamide Riboside to Prevent Muscle Fatigue of Barrows Subjected to a Performance Test.

Hennesy H, Gravely M, Alambarrio D, Brannen S, McDonald J, Devane S Metabolites. 2024; 14(8).

PMID: 39195520 PMC: 11355988. DOI: 10.3390/metabo14080424.


Effects of static exercises on hip muscle fatigue and knee wobble assessed by surface electromyography and inertial measurement unit data.

Dyer O, Seeley M, Wheatley B Sci Rep. 2024; 14(1):10448.

PMID: 38714802 PMC: 11076610. DOI: 10.1038/s41598-024-61325-7.


References
1.
Raccagni C, Gassner H, Eschlboeck S, Boesch S, Krismer F, Seppi K . Sensor-based gait analysis in atypical parkinsonian disorders. Brain Behav. 2018; 8(6):e00977. PMC: 5991583. DOI: 10.1002/brb3.977. View

2.
Kalron A . Association between perceived fatigue and gait parameters measured by an instrumented treadmill in people with multiple sclerosis: a cross-sectional study. J Neuroeng Rehabil. 2015; 12:34. PMC: 4403837. DOI: 10.1186/s12984-015-0028-2. View

3.
Sacco R, Bussman R, Oesch P, Kesselring J, Beer S . Assessment of gait parameters and fatigue in MS patients during inpatient rehabilitation: a pilot trial. J Neurol. 2010; 258(5):889-94. DOI: 10.1007/s00415-010-5821-z. View

4.
Borg G . Psychophysical bases of perceived exertion. Med Sci Sports Exerc. 1982; 14(5):377-81. View

5.
Flachenecker F, Gassner H, Hannik J, Lee D, Flachenecker P, Winkler J . Objective sensor-based gait measures reflect motor impairment in multiple sclerosis patients: Reliability and clinical validation of a wearable sensor device. Mult Scler Relat Disord. 2020; 39:101903. DOI: 10.1016/j.msard.2019.101903. View