» Articles » PMID: 33231430

Top-Down Proteomics of Endogenous Membrane Proteins Enabled by Cloud Point Enrichment and Multidimensional Liquid Chromatography-Mass Spectrometry

Overview
Journal Anal Chem
Specialty Chemistry
Date 2020 Nov 24
PMID 33231430
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Although top-down proteomics has emerged as a powerful strategy to characterize proteins in biological systems, the analysis of endogenous membrane proteins remains challenging due to their low solubility, low abundance, and the complexity of the membrane subproteome. Here, we report a simple but effective enrichment and separation strategy for top-down proteomics of endogenous membrane proteins enabled by cloud point extraction and multidimensional liquid chromatography coupled to high-resolution mass spectrometry (MS). The cloud point extraction efficiently enriched membrane proteins using a single extraction, eliminating the need for time-consuming ultracentrifugation steps. Subsequently, size-exclusion chromatography (SEC) with an MS-compatible mobile phase (59% water, 40% isopropanol, 1% formic acid) was used to remove the residual surfactant and fractionate intact proteins (6-115 kDa). The fractions were separated further by reversed-phase liquid chromatography (RPLC) coupled with MS for protein characterization. This method was applied to human embryonic kidney cells and cardiac tissue lysates to enable the identification of 188 and 124 endogenous integral membrane proteins, respectively, some with as many as 19 transmembrane domains.

Citing Articles

Mass spectrometry-intensive top-down proteomics: an update on technology advancements and biomedical applications.

Xu T, Wang Q, Wang Q, Sun L Anal Methods. 2024; 16(28):4664-4682.

PMID: 38973469 PMC: 11257149. DOI: 10.1039/d4ay00651h.


[Applications of high performance liquid chromatography-mass spectrometry in proteomics].

Liu W, Weng L, Gao M, Zhang X Se Pu. 2024; 42(7):601-612.

PMID: 38966969 PMC: 11224944. DOI: 10.3724/SP.J.1123.2023.11006.


Small-Scale Serial Size Exclusion Chromatography (sSEC) for High Sensitivity Top-Down Proteomics of Large Proteoforms.

Rogers H, Melby J, Ehlers L, Fischer M, Larson E, Gao Z Anal Chem. 2024; .

PMID: 38315630 PMC: 11298573. DOI: 10.1021/acs.analchem.3c05733.


Multidimensional Separations in Top-Down Proteomics.

Guo Y, Cupp-Sutton K, Zhao Z, Anjum S, Wu S Anal Sci Adv. 2024; 4(5-6):181-203.

PMID: 38188188 PMC: 10769458. DOI: 10.1002/ansa.202300016.


Phosphorylation Sites of the Gastric Inhibitory Polypeptide Receptor (GIPR) Revealed by Trapped-Ion-Mobility Spectrometry Coupled to Time-of-Flight Mass Spectrometry (TIMS-TOF MS).

Brown K, Morris R, Eckhardt S, Ge Y, Gellman S J Am Chem Soc. 2023; 145(51):28030-28037.

PMID: 38091482 PMC: 10842860. DOI: 10.1021/jacs.3c09078.


References
1.
Garavito R, Ferguson-Miller S . Detergents as tools in membrane biochemistry. J Biol Chem. 2001; 276(35):32403-6. DOI: 10.1074/jbc.R100031200. View

2.
Kar U, Simonian M, Whitelegge J . Integral membrane proteins: bottom-up, top-down and structural proteomics. Expert Rev Proteomics. 2017; 14(8):715-723. PMC: 6310004. DOI: 10.1080/14789450.2017.1359545. View

3.
Waitt G, Xu R, Wisely G, Williams J . Automated in-line gel filtration for native state mass spectrometry. J Am Soc Mass Spectrom. 2007; 19(2):239-45. DOI: 10.1016/j.jasms.2007.05.008. View

4.
Eichacker L, Granvogl B, Mirus O, Muller B, Miess C, Schleiff E . Hiding behind hydrophobicity. Transmembrane segments in mass spectrometry. J Biol Chem. 2004; 279(49):50915-22. DOI: 10.1074/jbc.M405875200. View

5.
Mi H, Muruganujan A, Thomas P . PANTHER in 2013: modeling the evolution of gene function, and other gene attributes, in the context of phylogenetic trees. Nucleic Acids Res. 2012; 41(Database issue):D377-86. PMC: 3531194. DOI: 10.1093/nar/gks1118. View