The ACE1 Electrical Impedance Tomography System for Thoracic Imaging

Abstract

The design and performance of the ACE1 (Active Complex Electrode) electrical impedance tomography system for single-ended phasic voltage measurements is presented. The design of the hardware and calibration procedures allow for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.

Citing Articles

ACT5 Electrical Impedance Tomography System.

Shishvan O, Abdelwahab A, Barbosa da Rosa N, Saulnier G, Mueller J, Newell J IEEE Trans Biomed Eng. 2023; 71(1):227-236.

PMID: 37459258 PMC: 10798853. DOI: 10.1109/TBME.2023.3295771.


Improved resolution of D-bar images of ventilation using a Schur complement property and an anatomical atlas.

Santos T, Nakanishi R, Leon Bueno de Camargo E, Amato M, Kaipio J, Lima R Med Phys. 2022; 49(7):4653-4670.

PMID: 35411573 PMC: 9544658. DOI: 10.1002/mp.15669.


Electrical Impedance Tomography - Recent Applications and Developments.

Mansouri S, Alharbi Y, Haddad F, Chabcoub S, Alshrouf A, Abd-Elghany A J Electr Bioimpedance. 2022; 12(1):50-62.

PMID: 35069942 PMC: 8667811. DOI: 10.2478/joeb-2021-0007.


A Point-Matching Method of Moment with Sparse Bayesian Learning Applied and Evaluated in Dynamic Lung Electrical Impedance Tomography.

Dimas C, Alimisis V, Uzunoglu N, Sotiriadis P Bioengineering (Basel). 2021; 8(12).

PMID: 34940344 PMC: 8698777. DOI: 10.3390/bioengineering8120191.


Practical Implementation of a Novel Output Impedance Measurement Technique for EIT System While Attached to a Load.

Shishvan O, Abdelwahab A, Saulnier G Annu Int Conf IEEE Eng Med Biol Soc. 2021; 2021:3952-3956.

PMID: 34892096 PMC: 9310546. DOI: 10.1109/EMBC46164.2021.9629839.


References
1.
Isaacson D . Distinguishability of conductivities by electric current computed tomography. IEEE Trans Med Imaging. 1986; 5(2):91-5. DOI: 10.1109/TMI.1986.4307752. View

2.
Putensen C, Wrigge H, Zinserling J . Electrical impedance tomography guided ventilation therapy. Curr Opin Crit Care. 2007; 13(3):344-50. DOI: 10.1097/MCC.0b013e328136c1e2. View

3.
Herrera C, Vallejo M, Mueller J, Lima R . Direct 2-D reconstructions of conductivity and permittivity from EIT data on a human chest. IEEE Trans Med Imaging. 2014; 34(1):267-74. PMC: 6288077. DOI: 10.1109/TMI.2014.2354333. View

4.
Lowhagen K, Lundin S, Stenqvist O . Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography. Minerva Anestesiol. 2010; 76(12):1024-35. View

5.
Rigaud B, Shi Y, Chauveau N, Morucci J . Experimental acquisition system for impedance tomography with active electrode approach. Med Biol Eng Comput. 1993; 31(6):593-9. DOI: 10.1007/BF02441807. View