» Articles » PMID: 33163229

Comparative Analysis of Visual Performance and Astigmatism Tolerance with Monofocal, Bifocal, and Extended Depth-of-Focus Intraocular Lenses Targeting Slight Myopia

Overview
Journal J Ophthalmol
Publisher Wiley
Specialty Ophthalmology
Date 2020 Nov 9
PMID 33163229
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare the visual performance and astigmatism tolerance of 3 intraocular lens (IOL) groups: monofocal, bifocal, and extended depth-of-focus (EDOF) IOLs targeting slight myopia.

Methods: Overall, there were 60 cataract surgery eyes from 60 patients with implantation of a monofocal, bifocal, or EDOF IOL (20 eyes in each IOL group). The EDOF IOLs targeted slight myopia (-0.25 to -0.75 ). Intragroup comparison of visual acuity, defocus curve, objective optical quality, contrast sensitivity, visual function questionnaire scores, patients' overall satisfaction, and the astigmatism tolerance was performed 3 months after surgery.

Results: The EDOF group provided equivalently excellent distance visual outcomes (0.06 ± 0.12) as the monofocal (0.06 ± 0.09) and bifocal (0.03 ± 0.09) groups (=0.554), better intermediate vision than the other 2 groups ( < 0.05), and similarly satisfactory near visual outcomes (0.23 ± 0.16 at 20 cm, and 0.17 ± 0.14 at 33 cm) as the bifocal group (0.28 ± 0.14 at 20 cm and 0.08 ± 0.10 at 33 cm) ( > 0.05). The contrast sensitivity of EDOF IOL was slightly decreased compared to that of monofocal IOL, but it was better than that of bifocal IOL. The EDOF group showed significantly higher satisfaction than the bifocal group did when preoperative corneal astigmatism was 0.75 or greater (=0.009). A significant negative correlation between the corneal astigmatism and patient satisfaction was observed in only the bifocal group.

Conclusions: The EDOF IOLs targeting slight myopia offered satisfactory visual outcomes at an extended range from far to near distances. The EDOF and monofocal IOLs showed a better tolerance to astigmatism than did the bifocal IOL.

Citing Articles

Changes in visual performance after implantation of different intraocular lenses.

Li B, Huang H, Huang M, Guo S, Gao L, Zeng Y Int J Ophthalmol. 2024; 17(7):1273-1282.

PMID: 39026905 PMC: 11246933. DOI: 10.18240/ijo.2024.07.12.


Biometric factors associated with the postoperative visual performance of a multifocal intraocular lens.

Xu J, Yang F, Lin P, Qian D, Zheng T Heliyon. 2024; 10(11):e31867.

PMID: 38845945 PMC: 11154599. DOI: 10.1016/j.heliyon.2024.e31867.


Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens.

Kenia V, Kenia R, Mudaliya L, Pirdankar O Taiwan J Ophthalmol. 2023; 13(3):341-345.

PMID: 38089518 PMC: 10712750. DOI: 10.4103/tjo.tjo_16_22.


Managing low corneal astigmatism in patients with presbyopia correcting intraocular lenses: a narrative review.

Rocha-de-Lossada C, Rodriguez-Vallejo M, Rodriguez-Calvo-de-Mora M, Ribeiro F, Fernandez J BMC Ophthalmol. 2023; 23(1):254.

PMID: 37280550 PMC: 10243013. DOI: 10.1186/s12886-023-03003-2.


Clinical Performance of Extended Depth of Focus (EDOF) Intraocular Lenses - A Retrospective Comparative Study of Mini Well Ready and Symfony.

Nowik K, Nowik K, Kanclerz P, Szaflik J Clin Ophthalmol. 2022; 16:1613-1621.

PMID: 35651536 PMC: 9150758. DOI: 10.2147/OPTH.S341698.


References
1.
Labiris G, Giarmoukakis A, Patsiamanidi M, Papadopoulos Z, Kozobolis V . Mini-monovision versus multifocal intraocular lens implantation. J Cataract Refract Surg. 2014; 41(1):53-7. DOI: 10.1016/j.jcrs.2014.06.015. View

2.
Cochener B, Boutillier G, Lamard M, Auberger-Zagnoli C . A Comparative Evaluation of a New Generation of Diffractive Trifocal and Extended Depth of Focus Intraocular Lenses. J Refract Surg. 2018; 34(8):507-514. DOI: 10.3928/1081597X-20180530-02. View

3.
Ruiz-Mesa R, Abengozar-Vela A, Ruiz-Santos M . A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens. Eur J Ophthalmol. 2017; 28(2):182-187. DOI: 10.5301/ejo.5001029. View

4.
Sachdev G, Ramamurthy S, Sharma U, Dandapani R . Visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens: A prospective study. Indian J Ophthalmol. 2018; 66(3):407-410. PMC: 5859596. DOI: 10.4103/ijo.IJO_813_17. View

5.
Ganesh S, Brar S, Pawar A, Relekar K . Visual and Refractive Outcomes following Bilateral Implantation of Extended Range of Vision Intraocular Lens with Micromonovision. J Ophthalmol. 2018; 2018:7321794. PMC: 5818926. DOI: 10.1155/2018/7321794. View