» Articles » PMID: 33149984

Single Wavelength Measurements of Absorption Coefficients Based on Iso-pathlength Point

Overview
Specialty Radiology
Date 2020 Nov 5
PMID 33149984
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

In optical sensing, to reveal the chemical composition of tissues, the main challenge is isolating absorption from scattering. Most techniques use multiple wavelengths, which adds an error due to the optical pathlength differences. We suggest using a unique measurement angle for cylindrical tissues, the iso-pathlength (IPL) point, which depends on tissue geometry only (specifically the effective radius). We present a method for absorption assessment from a single wavelength at multiple measurement angles. The IPL point presented similar optical pathlengths for different tissues, both in simulation and experiments, hence it is optimal. Finally, measurements validated our proposed method.

Citing Articles

Algorithm for monitoring water quality parameters in optical systems based on artificial intelligence data mining.

Su J, Xu W, Lin Z Sci Rep. 2024; 14(1):28142.

PMID: 39548118 PMC: 11568268. DOI: 10.1038/s41598-024-76700-7.


A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation.

Katan M, Pearl O, Tzroya A, Duadi H, Fixler D Biosensors (Basel). 2024; 14(3).

PMID: 38534239 PMC: 10968215. DOI: 10.3390/bios14030132.


Optical Method for Detection and Classification of Heavy Metal Contaminants in Water Using Iso-pathlength Point Characterization.

Tzroya A, Duadi H, Fixler D ACS Omega. 2024; 9(6):6986-6993.

PMID: 38371777 PMC: 10870376. DOI: 10.1021/acsomega.3c08792.


Detecting Contaminants in Water Based on Full Scattering Profiles within the Single Scattering Regime.

Tzroya A, Erblich S, Duadi H, Fixler D ACS Omega. 2023; 8(26):23733-23738.

PMID: 37426274 PMC: 10323954. DOI: 10.1021/acsomega.3c01977.


Beer-Lambert law for optical tissue diagnostics: current state of the art and the main limitations.

Oshina I, Spigulis J J Biomed Opt. 2021; 26(10).

PMID: 34713647 PMC: 8553265. DOI: 10.1117/1.JBO.26.10.100901.

References
1.
Beiderman Y, Amsel A, Tzadka Y, Fixler D, Mico V, Garcia J . A microscope configuration for nanometer 3-D movement monitoring accuracy. Micron. 2010; 42(4):366-75. DOI: 10.1016/j.micron.2010.05.020. View

2.
van der Zee P, Arridge S, Cope M, Delpy D . The effect of optode positioning on optical pathlength in near infrared spectroscopy of brain. Adv Exp Med Biol. 1990; 277:79-84. DOI: 10.1007/978-1-4684-8181-5_11. View

3.
Bhatt M, Ayyalasomayajula K, Yalavarthy P . Generalized Beer-Lambert model for near-infrared light propagation in thick biological tissues. J Biomed Opt. 2016; 21(7):76012. DOI: 10.1117/1.JBO.21.7.076012. View

4.
Delpy D, Cope M, van der Zee P, Arridge S, Wray S, Wyatt J . Estimation of optical pathlength through tissue from direct time of flight measurement. Phys Med Biol. 1988; 33(12):1433-42. DOI: 10.1088/0031-9155/33/12/008. View

5.
Xiao J, Yao L, Sun Y, Sobel E, He J, Jiang H . Quantitative two-dimensional photoacoustic tomography of osteoarthritis in the finger joints. Opt Express. 2010; 18(14):14359-65. DOI: 10.1364/OE.18.014359. View