» Articles » PMID: 33147757

Inter-Stage Output Voltage Amplitude Improvement Circuit Integrated with Class-B Transmit Voltage Amplifier for Mobile Ultrasound Machines

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Nov 5
PMID 33147757
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Piezoelectric transducers are triggered by the output voltage signal of a transmit voltage amplifier (TVA). In mobile ultrasound instruments, the sensitivity of piezoelectric transducers is a critical parameter under limited power supply from portable batteries. Therefore, the enhancement of the output voltage amplitude of the amplifier under limited power supply could increase the sensitivity of the piezoelectric transducer. Several-stage TVAs are used to increase the voltage amplitude. However, inter-stage design issues between each TVA block may reduce the voltage amplitude and bandwidth because the electronic components of the amplifier are nonlinearly operated at the desired frequency ranges. To compensate for this effect, we propose a novel inter-stage output voltage amplitude improvement (OVAI) circuit integrated with a class-B TVA circuit. We performed fundamental A-mode pulse-echo tests using a 15-MHz immersion-type piezoelectric transducer to verify the design. The echo amplitude and bandwidth when using an inter-stage OVAI circuit integrated with a class-B TVA circuit (696 mV and 29.91%, respectively) were higher than those obtained when using only the class-B TVA circuit (576 mV and 24.21%, respectively). Therefore, the proposed OVAI circuit could be beneficial for increasing the output amplitude of the class-B TVA circuit for mobile ultrasound machines.

Citing Articles

Radiation-induced acoustic signal denoising using a supervised deep learning framework for imaging and therapy monitoring.

Jiang Z, Wang S, Xu Y, Sun L, Gonzalez G, Chen Y Phys Med Biol. 2023; 68(23).

PMID: 37820684 PMC: 11000456. DOI: 10.1088/1361-6560/ad0283.


Harmonic-Reduced Bias Circuit for Ultrasound Transducers.

Choi H Sensors (Basel). 2023; 23(9).

PMID: 37177641 PMC: 10181787. DOI: 10.3390/s23094438.


An Inverse Class-E Power Amplifier for Ultrasound Transducer.

Choi H Sensors (Basel). 2023; 23(7).

PMID: 37050526 PMC: 10098776. DOI: 10.3390/s23073466.


A Doherty Power Amplifier for Ultrasound Instrumentation.

Choi H Sensors (Basel). 2023; 23(5).

PMID: 36904610 PMC: 10007245. DOI: 10.3390/s23052406.


Novel dual-resistor-diode limiter circuit structures for high-voltage reliable ultrasound receiver systems.

Choi H Technol Health Care. 2022; 30(S1):513-520.

PMID: 35124625 PMC: 9028643. DOI: 10.3233/THC-228047.


References
1.
Kim J, Kim K, Choe S, Choi H . Development of an Accurate Resonant Frequency Controlled Wire Ultrasound Surgical Instrument. Sensors (Basel). 2020; 20(11). PMC: 7309115. DOI: 10.3390/s20113059. View

2.
Hu C, Snook K, Cao P, Shung K . High-frequency ultrasound annular array imaging. Part II: digital beamformer design and imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2006; 53(2):309-16. DOI: 10.1109/tuffc.2006.1593369. View

3.
Gao Z, Gui P . A look-up-table digital predistortion technique for high-voltage power amplifiers in ultrasonic applications. IEEE Trans Ultrason Ferroelectr Freq Control. 2012; 59(7):1550-7. DOI: 10.1109/TUFFC.2012.2354. View

4.
Kim J, You K, Choe S, Choi H . Wireless Ultrasound Surgical System with Enhanced Power and Amplitude Performances. Sensors (Basel). 2020; 20(15). PMC: 7435488. DOI: 10.3390/s20154165. View

5.
Choi H, Park C, Kim J, Jung H . Bias-Voltage Stabilizer for HVHF Amplifiers in VHF Pulse-Echo Measurement Systems. Sensors (Basel). 2017; 17(10). PMC: 5676603. DOI: 10.3390/s17102425. View