Does Vacuum Mixing Affect Diameter Shrinkage of a PMMA Cement Mantle During in Vitro Cemented Acetabulum Implantation?

Overview
Date 2020 Oct 15
PMID 33054541
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Radiolucent lines on immediate postoperative cemented acetabular component radiographs between the PMMA bone cement mantle and bone are an indicator of an increased risk of early loosening. The cause of these lines has yet to be identified. Thermal and chemical necrosis, fluid interposition and cement shrinkage have all been suggested in the literature. The aim of the study reported here was to take an engineering approach - eliminating confounding variables present during surgery - to quantify the size of the interstice created by cement shrinkage when a 50 mm diameter flanged acetabular cup is implanted in a model acetabulum with a 52 mm hemispherical bore under controlled conditions using vacuum and non-vacuum mixed cement. Irrespective of the mixing method used, a significant interstice was created between the bone cement and the mock acetabulum. When the cement was mixed under vacuum the interstice created between the mock acetabulum and the cement mantle was 0.60 mm ± 0.09 mm; when the cement was mixed under non-vacuum conditions the interstice created was 0.39 mm ± 0.15 mm. Possible explanations for radiolucent lines are discussed.

Citing Articles

The addition of a flange does not improve the pressure generated during cemented acetabular cup implantation.

Boote A, Deehan D, Rankin K, Swailes D, Hyde P J Biomed Mater Res B Appl Biomater. 2022; 110(10):2290-2298.

PMID: 35657060 PMC: 9540581. DOI: 10.1002/jbm.b.35077.

References
1.
Parsch D, Diehm C, New A, Schneider S, Breusch S . A new bleeding model of the human acetabulum and a pilot comparison of 2 different cement pressurizers. J Arthroplasty. 2004; 19(3):381-6. DOI: 10.1016/j.arth.2003.09.014. View

2.
Bishop N, Ferguson S, Tepic S . Porosity reduction in bone cement at the cement-stem interface. J Bone Joint Surg Br. 1996; 78(3):349-56. View

3.
DeLee J, CHARNLEY J . Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976; (121):20-32. View

4.
Lewis G . Properties of acrylic bone cement: state of the art review. J Biomed Mater Res. 1997; 38(2):155-82. DOI: 10.1002/(sici)1097-4636(199722)38:2<155::aid-jbm10>3.0.co;2-c. View

5.
Ritter M, Zhou H, Keating C, Keating E, Faris P, Meding J . Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties. J Bone Joint Surg Br. 2000; 81(6):982-6. DOI: 10.1302/0301-620x.81b6.9634. View