» Articles » PMID: 33022969

Prediction Model for Airborne Microorganisms Using Particle Number Concentration As Surrogate Markers in Hospital Environment

Overview
Publisher MDPI
Date 2020 Oct 7
PMID 33022969
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Indoor microbiological air quality, including airborne bacteria and fungi, is associated with hospital-acquired infections (HAIs) and emerging as an environmental issue in hospital environment. Many studies have been carried out based on culture-based methods to evaluate bioaerosol level. However, conventional biomonitoring requires laborious process and specialists, and cannot provide data quickly. In order to assess the concentration of bioaerosol in real-time, particles were subdivided according to the aerodynamic diameter for surrogate measurement. Particle number concentration (PNC) and meteorological conditions selected by analyzing the correlation with bioaerosol were included in the prediction model, and the forecast accuracy of each model was evaluated by the mean absolute percentage error (MAPE). The prediction model for airborne bacteria demonstrated highly accurate prediction ( = 0.804, MAPE = 8.5%) from PNC1-3, PNC3-5, and PNC5-10 as independent variables. Meanwhile, the fungal prediction model showed reasonable, but weak, prediction results ( = 0.489, MAPE = 42.5%) with PNC3-5, PNC5-10, PNC > 10, and relative humidity. As a result of external verification, even when the model was applied in a similar hospital environment, the bioaerosol concentration could be sufficiently predicted. The prediction model constructed in this study can be used as a pre-assessment method for monitoring microbial contamination in indoor environments.

Citing Articles

The Effectiveness of a Novel Air-Barrier Device for Aerosol Reduction in a Dental Environment: Computational Fluid Dynamics Simulation.

Ma X, Kim W, Lee J, Han D, Lee S, Kim J Bioengineering (Basel). 2023; 10(8).

PMID: 37627832 PMC: 10452020. DOI: 10.3390/bioengineering10080947.


Microbial Indoor Air Quality and Associated Factors in Jimma Town Prison Administration, Southwestern Ethiopia.

Ahmednur M, Awel H, Haile G Environ Health Insights. 2022; 16:11786302221118842.

PMID: 36003416 PMC: 9393662. DOI: 10.1177/11786302221118842.

References
1.
Stocks G, Self S, Thompson B, Adame X, OConnor D . Predicting bacterial populations based on airborne particulates: a study performed in nonlaminar flow operating rooms during joint arthroplasty surgery. Am J Infect Control. 2009; 38(3):199-204. DOI: 10.1016/j.ajic.2009.07.006. View

2.
Sundell J . On the history of indoor air quality and health. Indoor Air. 2004; 14 Suppl 7:51-8. DOI: 10.1111/j.1600-0668.2004.00273.x. View

3.
Park C, Park J, Lee S, Hwang J . Real-time monitoring of bioaerosols via cell-lysis by air ion and ATP bioluminescence detection. Biosens Bioelectron. 2013; 52:379-83. DOI: 10.1016/j.bios.2013.09.015. View

4.
Frankel M, Beko G, Timm M, Gustavsen S, Hansen E, Madsen A . Seasonal variations of indoor microbial exposures and their relation to temperature, relative humidity, and air exchange rate. Appl Environ Microbiol. 2012; 78(23):8289-97. PMC: 3497365. DOI: 10.1128/AEM.02069-12. View

5.
Landrin A, Bissery A, Kac G . Monitoring air sampling in operating theatres: can particle counting replace microbiological sampling?. J Hosp Infect. 2005; 61(1):27-9. DOI: 10.1016/j.jhin.2005.03.002. View