» Articles » PMID: 33010932

The Potential Utility of Abbreviated Breast MRI (FAST MRI) As a Tool for Breast Cancer Screening: a Systematic Review and Meta-analysis

Overview
Journal Clin Radiol
Specialty Radiology
Date 2020 Oct 4
PMID 33010932
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: To synthesise evidence comparing abbreviated breast magnetic resonance imaging (abMRI) to full-protocol MRI (fpMRI) in breast cancer screening.

Materials And Methods: A systematic search was undertaken in multiple databases. Cohort studies without enrichment, presenting accuracy data of abMRI in screening, for any level of risk (population, moderate, high risk) were included. Level of evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE). Meta-analyses (bivariate random effects model) were performed for abMRI, with fpMRI and histology from fpMRI-positive cases as reference standard, and with follow-up to symptomatic detection added to the fpMRI. The review also covers evidence comparing abMRI with mammographic techniques.

Results: The title and abstract review retrieved 23 articles. Five studies (six articles) were included (2,763 women, 3,251 screening rounds). GRADE assessment of the evidence was very low because the reference standard was interpreted with knowledge of the index test and biopsy was not obtained for all abMRI positives. The overall sensitivity for abMRI, with fpMRI (and histology for fpMRI positives) as reference standard, was 94.8% (95% confidence interval [CI] 85.5-98.2) and specificity as 94.6% (95% CI: 91.5-96.6). Three studies (1,450 women, 1,613 screening rounds) presented follow-up data, enabling comparison between abMRI and fpMRI. Sensitivities and specificities for abMRI did not differ significantly from those for fpMRI (p=0.83 and p=0.37, respectively).

Conclusion: A very low level of evidence suggests abMRI could be accurate for breast cancer screening. Research is required, with follow-up to interval cancer, to determine the effect its use could have on clinical outcome.

Citing Articles

Accuracy of Abbreviated Breast MRI in Diagnosing Breast Cancer in Women with Dense Breasts Compared with Standard Imaging Modalities.

Aloufi A, Khoumais N, Ahmed F, Hosawi S, Sulimani S, Abunayyan D Saudi J Med Med Sci. 2025; 13(1):7-17.

PMID: 39935997 PMC: 11809753. DOI: 10.4103/sjmms.sjmms_58_24.


Comparative diagnostic efficacy of abbreviated and full protocol breast MRI: a systematic review and a meta-analysis.

Pesapane F, Battaglia O, Rotili A, Gnocchi G, DEcclesiis O, Bellerba F Br J Radiol. 2024; 97(1164):1915-1924.

PMID: 39400335 PMC: 11573129. DOI: 10.1093/bjr/tqae196.


Maintaining accuracy and expanding access: evaluating the efficacy of the Botucatu Abbreviated Breast MRI Protocol.

Pessoa E, Moares T, de Amorim H, Couto H, Abbade J, Shinomia S Rev Bras Ginecol Obstet. 2024; 46.

PMID: 39176207 PMC: 11341192. DOI: 10.61622/rbgo/2024rbgo55.


Optimising the diagnostic accuracy of First post-contrAst SubtracTed breast MRI (FAST MRI) through interpretation-training: a multicentre e-learning study, mapping the learning curve of NHS Breast Screening Programme (NHSBSP) mammogram readers using....

Jones L, Marshall A, Geach R, Elangovan P, OFlynn E, Timlin T Breast Cancer Res. 2024; 26(1):85.

PMID: 38807211 PMC: 11134713. DOI: 10.1186/s13058-024-01846-1.


Diagnostic validity of abbreviated breast MRI in the diagnosis of breast cancer: a comparative study to the full breast MRI protocol using BI-RADS.

Ebaid N, Assy M, Eldin A Pol J Radiol. 2024; 89:e80-e87.

PMID: 38510549 PMC: 10953509. DOI: 10.5114/pjr.2024.135474.